ArticlePloS one2022
An accurate wearable hydration sensor: Real-world evaluation of practical use.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 22 citations in OpenAlex.
- Recent Advancements in Wearable Hydration-Monitoring Technologies: Scoping Review of Sensors, Trends, and Future Directions.JMIR mHealth and uHealth · 2025Article
- Non-invasive approaches to hydration assessment: a literature review.Urolithiasis · 2024Review
- Hydration Status Assessment in Older Patients.Deutsches Arzteblatt international · 2023Review
- An exploratory study of dynamic foot shape measurements with 4D scanning system.Scientific reports · 2023Article
- How to Monitor Hydration Status and Urine Dilution in Patients with Nephrolithiasis.Nutrients · 2023Review
- Pilot Study of a Wearable Hydration Monitor in Haemodialysis Patients: Haemodialysis Outcomes & Patient Empowerment Study 02.Digital biomarkersArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A wearable body hydration sensor employing photoplethysmographic and galvanic biosensors was field evaluated using 240 human participants with equal numbers of men and women volunteers. Monitoring of water mass loss due to perspiration was performed by medical balance measurements following one of two different treadmill physical exercise regimens over 90 minutes in 15-minute intervals with intervening 10-minute rest periods. Participants wore two different models of the dehydration body monitor device mated to commercially-available smartwatches (Samsung Gear S2 and Samsung Gear Fit2). Device output was recorded by Bluetooth wireless link to a standard smartphone in 20-second blocks. Comparison of the devices with the standard measurement method (change in body mass measured by medical balance) indicated very close agreement between changes in body water mass and device output (percent normalized mean root square error averaged approximately 2% for all participants). Bland-Altman analyses of method agreement indicated that <5% of participant values fell outside of the 95% confidence interval limits of agreement and all measured value differences were normally distributed around the line of equality. The results of this first-ever field trial of a practical, wearable hydration monitor suggests that this device will be a reliable tool to aid in geriatric hydration monitoring and physical training scenarios.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.