Evidence map›Paper›PMID 35999410›Full record

ArticleNeurocritical care2023

Predictive Values for Time from Transducer Stopcock Closure to Accurate Intracranial Pressure Reading.

Corrie Earthman, Kathrina Siaron, Jennifer Wilson, DaiWai M Olson

Abstract read
PubMed Publisher
In one paragraph

Article in Neurocritical care, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Corrie EarthmanTexas Woman's University, Dallas, TX, USA.
Kathrina SiaronUniversity of Texas Southwestern Medical Center, Dallas, TX, 75390, USA.
Jennifer WilsonTexas Woman's University, Dallas, TX, USA.
DaiWai M OlsonUniversity of Texas Southwestern Medical Center, Dallas, TX, 75390, USA. daiwai.olson@utsouthwestern.edu.ORCID 0000-0002-9280-078X
Texas Woman's University · USSouthwestern Medical Center · USThe University of Texas Southwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhen using an external ventricular drain (EVD) to monitor intracranial pressure (ICP), nurses need to know how long to wait after each manipulation of the transducer before the displayed ICP value represents an accurate signal. This study explores ICP signal equilibration time (EqT) under clinical conditions.

methodsThis was a prospective ex vivo study using a simulated skull, standard EVD tubing, and a strain gauge transducer. All 270 trials simulating 90 combinations of different pressures and common clinical conditions were completed in August 2021. Each trial was recorded on video. Videos were scored using video editing software to obtain the exact start and stop time for each trial.

resultsThe mean EqT was 44.90 (18.77) seconds. One hundred fifty (55.56%) observations did not reach their expected value within 60 s. The longest mean EqTs were noted when blood was present in the EVD tubing (57.67 [8.91] seconds), when air bubbles were in the tubing (57.41 [8.73] seconds), and when EVD tubing was not flat (level) (50.77 [15.43] seconds). An omnibus test comparing mean EqT for conditions with no variables manipulated (30.08 [16.07] seconds) against mean EqT for all others (47.18 [18.13] seconds) found that mean EqTs were significantly different (P < 0.001).

conclusionsEven when no additional variables were introduced, the mean EqTs were ~ 30 s. Common clinical variables increase the length of time before a transducer connected to an EVD will provide an accurate reading. Nurses should wait at least 30 s after turning the EVD stopcock before assuming ICP value reflects accurate ICP.

Indexed as

Intracranial PressureReadingDrainageHumansMonitoring, PhysiologicProspective StudiesExternal ventricular drainIntracranial pressureMeasurementMonitoringNeurocritical careNursing

Identifiers

PMID35999410
OpenAlexW4293262064

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.