Evidence map›Paper›PMID 35998187›Full record

ArticlePloS one2022

Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.

Kazuaki Amami, Akiomi Yoshihisa, Yuko Horikoshi, Shinya Yamada, Takeshi Nehashi, Naoko Hijioka, Minoru Nodera, Takashi Kaneshiro, Tetsuro Yokokawa, Tomofumi Misaka and 1 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Kazuaki AmamiDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Akiomi YoshihisaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.ORCID 0000-0001-5574-6617
Yuko HorikoshiDepartment of Clinical Laboratory Sciences, Fukushima Medical University School of Health Science, Fukushima, Japan.
Shinya YamadaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Takeshi NehashiDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Naoko HijiokaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Minoru NoderaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Takashi KaneshiroDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Tetsuro YokokawaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.ORCID 0000-0001-8197-3274
Tomofumi MisakaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Yasuchika TakeishiDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Fukushima Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA 12-lead electrocardiogram (ECG) and Holter ECG have been established as gold standards for detection of arrhythmias. Recently, wearable ECG monitoring devices have been available. Our purpose of the present study was to investigate whether a novel wearable electrode embedded in an undershirt is useful for ECG monitoring and detection of arrhythmias.

methodsWe studied 31 consecutive hospitalized patients who underwent catheter ablation of tachyarrhythmias. Patients equipped a wearable electrode and a lead CM5 of Holter ECG simultaneously, and total heart beats, maximum heart rate (HR), mean HR, minimum HR, detections of arrhythmias, such as atrial fibrillation, non-sustained ventricular tachycardia, and premature ventricular contractions (Lown's grade >II), were compared between the two methods using a Holter ECG analysis software.

resultsMedian recording time of ECG by wearable electrodes was 12.6 hours. Strong correlations between the two methods were observed in total heart beats (R = 0.999, P <0.001), maximum HR (R = 0.997, P <0.001), mean HR (R = 0.999, P <0.001), minimum HR (R = 0.989, P <0.001) and QRS duration (R = 0.900, P <0.001). Bland-Altman analysis showed excellent concordance between each parameter measured by two methods. In addition, the detection of atrial fibrillation (nine events), non-sustained ventricular tachycardia (two events), and premature ventricular contractions of Lown's grade >II (five events) were concordant in two methods. In addition, there were no significant difference in parameters of time-domain and frequency-domain analyses of heart rate variability between the two methods.

conclusionsThe usefulness of a novel electrode embedded in an undershirt is equivalent to that of a Holter ECG in monitoring the ECG and detection of arrythmias.

Indexed as

Atrial FibrillationTachycardia, VentricularVentricular Premature ComplexesWearable Electronic DevicesElectrocardiographyElectrocardiography, AmbulatoryElectrodesHumans

Identifiers

PMID35998187
PMCPMC9398013
OpenAlexW4292767261

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked