Evidence map›Paper›PMID 35997508›Full record

ArticleClinical oral implants research2022

In vitro effect of different implant decontamination methods in three intraosseous defect configurations.

Fernando Luengo, Javier Sanz-Esporrín, Fernando Noguerol, Ignacio Sanz-Martín, Ignacio Sanz-Sánchez, Mariano Sanz

Abstract read
In one paragraph

Article in Clinical oral implants research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fernando LuengoSection of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.ORCID https://orcid.org/0000-0001-8106-6615
Javier Sanz-EsporrínSection of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.ORCID https://orcid.org/0000-0003-0859-3149
Fernando NoguerolSection of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.
Ignacio Sanz-MartínPrivate practice Lausanne, Lausanne, Switzerland.ORCID https://orcid.org/0000-0001-7037-1163
Ignacio Sanz-SánchezSection of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.ORCID https://orcid.org/0000-0002-3698-4772
Mariano SanzSection of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.ORCID https://orcid.org/0000-0002-6293-5755

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis in vitro investigation was aimed to evaluate the cleaning ability of four mechanical devices designed for decontaminating implant surfaces. MATERIAL AND

methodsNinety-six implants were coated with permanent ink and inserted into 3D-printed resin blocks simulating three different intraosseous defect configurations (types Ib, Ic, and Ie). The four tested mechanical decontamination devices (air-polishing with glycine powder, rotating titanium brush, polyetheretherketone [PEEK]-coated ultrasonic tip, and stainless steel ultrasonic tip) were randomly applied onto the 5 mm exposed implant surface. Standardized photographs were taken from a frontal perspective and with a 30° angle coronally and apically to the implant axis. The area with remnant ink on the implant surface was calculated.

resultsAlthough none of the groups achieved complete ink removal, air-polishing with glycine and titanium brushes demonstrated a higher cleaning ability when compared with ultrasonic devices either with standard or PEEK tips for all three defect configurations. For the three tested models, the best cleaning ability in all groups was shown on implant surfaces without facing an intraosseous wall. Titanium brush was the most effective when the intraosseous walls existed. Cleaning effectiveness diminished in the threads located in the apical third, especially when using air-polishing and ultrasonic devices.

conclusionsTitanium brushes and air-polishing devices were more effective in removing artificial biofilm using this in vitro model, although their effectiveness was influenced by the presence of the intrabony component.

Indexed as

Dental ImplantsBenzophenonesDecontaminationGlycinePolymersSurface PropertiesTitaniumBenzophenonesDental ImplantsGlycinepolyetheretherketonePolymersTitaniumdecontaminationdental implantsperi-implantitistitanium

Identifiers

PMID35997508
PMCPMC9825956

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.