Validation of the RunScribe inertial measurement unit for walking gait measurement.

Max Lewin, Carina Price, Christopher Nester

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Max LewinSchool of Health and Society, University of Salford, Manchester, United Kingdom.ORCID 0000-0001-9129-8735
Carina PriceSchool of Health and Society, University of Salford, Manchester, United Kingdom.ORCID 0000-0002-5633-1250
Christopher NesterSchool of Health and Society, University of Salford, Manchester, United Kingdom.
University of Salford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe use of portable gait measurement systems in research is appealing to collect real-world data at low-cost, low participant burden, and without requirement for dedicated lab space. Most commercially available inertial measurement units (IMU's) designed for running only capture temporospatial data, the ability to capture biomechanics data such as shock and motion metrics with the RunScribe IMU makes it the closest to a lab alternative. The RunScribe system has been validated in running, however, is yet to be validated for walking.

methodQualisys motion capture, AMTI force plates, and Delsys Trigno accelerometers were used as gold standard lab measures for comparison against the RunScribe IMU. Twenty participants completed 10 footsteps per foot (20 total) measured by both systems simultaneously. Variables for validation included: Vertical Ground reaction force (GRF), instantaneous GRF rate, pronation excursion, pronation velocity, total shock, impact force, braking force. Interclass correlation (ICC) was used to determine agreement between the measurement systems, mean differences were used to evaluate group level accuracy.

resultsICC results showed moderate agreement between measurement systems when both limbs were averaged. The greatest agreement was seen for GRF rate, pronation excursion, and pronation velocity (ICC = 0.627, 0.616, 0.539), low agreement was seen for GRF, total shock, impact shock, braking shock (ICC = 0.269, 0.351, 0.244, 0.180). However mean differences show the greatest level of accuracy for GRF, GRF rate, and impact shock. DISCUSSION: Results show mixed agreement between the RunScribe and gold standard lab measures, and varied agreement across left and right limbs. Kinematic variables showed the greatest agreement, however GRF had the lowest relative mean difference for group results. The results show acceptable levels of agreement for most variables, however further work must be done to assess the repeatability and sensitivity of the RunScribe to be applied within areas such as footwear testing and gait retraining protocols.

Indexed as

GaitRunningBiomechanical PhenomenaFootHumansWalking

Identifiers

PMID35994458
PMCPMC9394823
OpenAlexW4292656976

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.