Retinal magnification factors at the fixation locus derived from schematic eyes with four individualized surfaces.

Xiaojing Huang, Trevor Anderson, Alfredo Dubra

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Retinal Changes From Hyperopia to Myopia: Not All Diopters Are Created Equal.Investigative ophthalmology & visual science · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Xiaojing HuangInstitute of Optics, University of Rochester, Rochester, NY 14620, USA.ORCID https://orcid.org/0000-0001-5150-985X
Trevor AndersonCylite Pty. Ltd., Notting Hill, Victoria, Australia.
Alfredo DubraByers Eye Institute, Stanford University, Palo Alto, CA 94303, USA.ORCID https://orcid.org/0000-0002-6506-9020
Cytel (United States) · USStanford University · USUniversity of Rochester · US

Funding

Stanford Vision Research CoreP30EY026877 · NEI · STANFORD UNIVERSITY · PI Jeffrey L Goldberg · 2017 to 2026
$8.0M
Increasing the isoplanatic patch in adaptive optics ophthalmoscopyR01EY032147 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2021 to 2025
$2.4M
Improving rigor and reproducibility in adaptive optics ophthalmoscopyR01EY031360 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2020 to 2023
$2.3M
Low Latency Eye-Motion CompensationR01EY032669 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2021 to 2024
$1.8M
NEI NIH HHS P30 EY026877NEI NIH HHS R01 EY031360NEI NIH HHS R01 EY032147NEI NIH HHS R01 EY032669
6 · The paper itself

Abstract

Retinal magnification factors (RMFs) allow the conversion of angles to lengths in retinal images. In this work, we propose paraxial and non-paraxial RMF calculation methods that incorporate the individual topography and separation of the anterior and posterior surfaces of the cornea and crystalline lens, assuming homogeneous ocular media. Across 34 eyes, the two RMF methods differ by 0.1% on average, due to surface tilt, decenter, and lack of rotational symmetry in the non-paraxial modeling, which results in up to 2.2% RMF variation with retinal meridian. Differences with widely used individualized RMF calculation methods are smallest for eyes with ∼24 mm axial length, and as large as 7.5% in a 29.7 mm long eye (15D myope). To better model the capture of retinal images, we propose the tracing of chief rays, instead of the scaling of posterior nodal or principal distances often used in RMF definitions. We also report that RMF scale change is approximately proportional to both refractive error and axial separation between the ophthalmoscope's exit pupil and the eye's entrance pupil, resulting in RMF changes as large as 13% for a 1cm displacement in a 15D myopic eye. Our biometry data shows weak correlation and statistical significance between surface radii and refractive error, as well as axial length, whether considering all eyes in the study, or just the high myopes, defined as those with refractive error sphere equivalent ≤ -4D. In contrast, vitreous thicknesses show a strong correlation (