Left bundle branch potential predicts better electrical synchrony in bradycardia patients receiving left bundle branch pacing.

Jingjuan Huang, Lina Guo, Weiwei Zhang, Ruogu Li, Ben He

Abstract read
In one paragraph

Article in BMC cardiovascular disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Assessing modified chest leads as a substitute for electrophysiological systems in left bundle branch area pacing.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jingjuan Huang *Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 W Huaihai Rd, Shanghai, 200030, China.
Lina Guo *Department of Ultrasound, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 W Huaihai Rd, Shanghai, 200030, China.
Weiwei ZhangDepartment of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 W Huaihai Rd, Shanghai, 200030, China.
Ruogu LiDepartment of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 W Huaihai Rd, Shanghai, 200030, China. 13564565961@163.com.
Ben HeDepartment of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 W Huaihai Rd, Shanghai, 200030, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft bundle branch pacing (LBBP) is a novel physiological pacing technology. We aim to explore the relation between LBB potential (LBB Po) and left ventricular (LV) electrical/mechanical synchrony in bradycardia patients without heart failure (HF) receiving LBBP.

methodsA total of 62 patients undergoing LBBP were categorized by LBB Po: the LBB Po positive (+) group and the LBB Po negative (-) group. The perioperative electrocardiographic and echocardiography parameters related to cardiac synchrony were analyzed.

resultsThere were 42 (67.74%) patients in the LBB Po (+) group and 20 patients in the LBB Po (-) group. Paced QRS duration (113.50 ± 17.65 ms vs. 123.40 ± 13.18 ms, P = 0.031) and stimulus left ventricular activation time (71.76 ± 3.53 ms vs. 74.45 ± 3.12 ms, P = 0.005) were shorter in the LBB Po (+) group than in the LBB Po (-) group. No significant differences in the LV mechanical synchrony (Ts-SD-12, 36.55 ± 19.76 vs. 39.95 ± 16.04, P = 0.505; PSD, 51.14 ± 17.69 vs. 45.65 ± 10.55, P = 0.205) between the two groups. There was not statistically difference in ventricular lead parameters measured intraoperative between the two groups. Compared with the LBB Po (-) group, the LBB Po (+) group showed a dramatically higher total procedure duration time (93.52 ± 9.18 min vs. 86.25 ± 10.54 min, p = 0.007) and fluoroscopy time for ventricle lead implantation (18.95 ± 3.43 min vs. 14.00 ± 3.16 min, p < 0.001).

conclusionsThe appearance of LBB Po may suggest better electrical synchrony during LBBP, but similar in LV mechanical synchrony. However, the total operation duration and fluoroscopy time of ventricular lead implantation in the LBB Po (+) group were longer. Therefore, it may be unnecessary to deliberately recognize the LBB Po when it is difficult to detect LBB Po and meet the LBBP criterion.

Indexed as

BradycardiaBundle of HisCardiac Pacing, ArtificialElectrocardiographyHeart Conduction SystemHumansBradycardiaLeft bundle branch pacingLeft bundle branch potentialLeft ventricular electrical synchronyLeft ventricular mechanical synchrony

Identifiers

PMID35986250
PMCPMC9389707

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.