ArticleScientific reports2022
Sample-centred shimming enables independent parallel NMR detection.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 14 citations in OpenAlex.
- Miniaturization and Optimization of NMR Shimsets Allow Efficient Field Shimming.Analytical chemistry · 2026Article
- Split spiral broadband double channel NMR detector facilitated by LTCC technology.Scientific reports · 2025Article
- Coherence locking in a parallel nuclear magnetic resonance probe defends against gradient field spillover.Magnetic resonance (Gottingen, Germany) · 2025Article
- Localized Shims Enable Low-Field Simultaneous Multinuclear NMR Spectroscopy.Analytical chemistry · 2024Article
- Artificial intelligence-driven shimming for parallel high field nuclear magnetic resonance.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Two major technical challenges facing parallel nuclear magnetic resonance (NMR) spectroscopy, at the onset, include the need to achieve exceptional [Formula: see text] homogeneity, and good inter-detector radiofrequency signal decoupling, and have remained as technical obstacles that limit high throughput compound screening via NMR. In this contribution, we consider a compact detector system, consisting of two NMR 'unit cell' resonators that implement parallel [Formula: see text] shimming with parallel radiofrequency detection, as a prototype NMR environment, pointing the way towards achieving accelerated NMR analysis. The utility of our approach is established by achieving local field correction within the bore of a 1.05T permanent magnet MRI. Our forerunner platform suppresses signal cross-coupling in the range of [Formula: see text] dB to [Formula: see text] dB, under a geometrically decoupled scheme, leading to a halving of the necessary inter-coil separation. In this permanent magnet environment, two decoupled parallel NMR detector sites simultaneously achieve narrow spectral linewidth, overcoming the spatial inhomogeneity of the magnet from 400 to 28 Hz.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.