Evidence map›Paper›PMID 35984837›Full record

ArticlePloS one2022

Effect of technologist and patient attributes on centering for body CT examinations: Influence of cultural and ethnic factors.

Antar Aly, Shadi Ebrahimian, Mohammed H Kharita, Mahmoud Heidous, Mohammad Zaya Ashruf, Davendra Kumar, Mannudeep K Kalra, Huda Mohd Al Naemi

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Antar AlyHamad Medical Corporation, Doha, Qatar.ORCID 0000-0002-2325-6610
Shadi EbrahimianDepartment of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States of America.
Mohammed H KharitaHamad Medical Corporation, Doha, Qatar.
Mahmoud HeidousHamad Medical Corporation, Doha, Qatar.
Mohammad Zaya AshrufHamad Medical Corporation, Doha, Qatar.
Davendra KumarHamad Medical Corporation, Doha, Qatar.
Mannudeep K KalraDepartment of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States of America.
Huda Mohd Al NaemiHamad Medical Corporation, Doha, Qatar.
Hamad Medical Corporation · QAHarvard University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

There are no published data on the effect of patient and technologist gender and ethnicity attributes on off-centering in CT. Therefore, we assessed the impact of patient and technologist variations on off-centering patients undergoing body CT. With institutional review board approval, our retrospective study included 1000 consecutive adult patients (age ranged 22-96 years; 756 males: 244 females) who underwent chest or abdomen CT examinations. We recorded patient (age, gender, nationality, body weight, height,), technologist gender, and scan-related (scanner vendor, body region imaged, scan length, CT dose index volume, dose length product) information. Lateral and anteroposterior (AP) diameters were recorded to calculate effective diameter and size-specific dose estimate (SSDE). Off-centering represented the distance between the anterior-posterior centers of the scan field of view and the patient at the level of carina (for chest CT) and iliac crest (for abdomen CT). About 76% of the patients (760/1000) were off-centered with greater off-centering for chest (22 mm) than for abdomen (15 mm). Although ethnicity or patient gender was not a significant determinant of off-centering, technologist-patient gender mismatch was associated with a significantly greater frequency of off-centering (p<0.001). Off-centering below the gantry isocenter was twice as common as off-centering above the gantry isocenter (p<0.001). The latter occurred more frequently in larger patients and was associated with higher radiation doses than those centered below the isocenter (p<0.001). Technologists' years of experience and patient factors profoundly affect the presence and extent of off-centering for both chest and abdomen CTs. Larger patients are more often off-centered than smaller patients.

Indexed as

EthnicityPatient PositioningAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedRadiation DosageRetrospective StudiesTomography, X-Ray ComputedYoung Adult

Identifiers

PMID35984837
PMCPMC9390905
OpenAlexW4292379713

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.