ArticleMusculoskeletal surgery2023
Direct anterior approach in total hip arthroplasty: influence of stem length on clinical and radiological outcomes at medium-term follow-up.
Article in Musculoskeletal surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Canal fill and radiographic comparison analysis of novel fully hydroxyapatite coated, variable triple-tapered geometry stems: one-year follow-up after direct anterior approach total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2025Article
- No significant differences in 60-day postoperative complication rates between conventional and shortened stems.Journal of experimental orthopaedics · 2023Article
- Femoral Head Autograft to Manage Acetabular Bone Loss Defects in THA for Crowe III Hips by DAA: Retrospective Study and Surgical Technique.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate the influence of short versus long stems implanted through a Direct Anterior Approach (DAA) on clinical and radiological outcomes in THA at medium-term follow-up (average follow-up of 44.8 months).
methods167 consecutive total hip arthroplasties treating patients affected by primary hip osteoarthritis were retrospectively evaluated. A standard-length stem (H-MAXs) was used in 70 patients, while a short metaphyseal-fitting femoral stem (MINIMA) was used in 97 patients. The Harris Hip Score (HHS) and Forgotten Joint Score-12 (FJS) were used as outcomes measurements. Post-operatively, Engh's score and Brooker classification were analyzed at 6 months, 1 year and every 2 years until the final FU. The correct size of the implant was evaluated determining the canal fill index (CFI), and all undersized stems were classified according to Magra classification.
resultsThe average HHS was 83 ± 13.4 in the standard stems group and 87 ± 14.1 for short stems group (p = 0.148). The average FJS was 87.9 ± 15.2 for patients in the standard stems group and 84.5 ± 17.7 with no significant differences (p = 0.327). None of the stems showed radiographic signs of instability (standard stems mean Engh's score: 19.25 versus short stems mean Engh's score: 19.50-p = 0.41). According to Brooker classification, no significant difference in severity was found using different stems (p = 0.715). A high rate of undersized stems was found (standard stems 24%-short stems 25%) but without statistical difference between groups (p = 0.078), while a different trend in malposition following the recent classification proposed by Magra et al. was observed evaluating all undersized stems (p = 0.0387).
conclusionsBoth groups achieved good and comparable patient-reported outcome measurements (PROMs) and radiographic stability with fixation observed by bone ingrowth. A high rate of undersized stems was found with a correlation between femoral stem length and specific pattern of malposition. Malalignment in Varus was frequent in shorter stems in contact proximally with medial calcar and distally with lateral cortex, while a uniform undersizing was observed for longer ones with a continuous margin around the stem. However, the stems never presented progressive radiolucent lines over the whole surface of the stem.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.