ArticleMedical physics2022
Deep learning-based virtual noncalcium imaging in multiple myeloma using dual-energy CT.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Intra-osseous Ice Ball Visualization During Cryoablation Using Photon-Counting Detector Computed Tomography: An In-Vivo Swine Pilot Study.Cardiovascular and interventional radiology · 2026Article
- State of the AI: Post-Deployment Monitoring of Radiology-Focused Internally Developed AI.Mayo Clinic proceedings. Digital health · 2026Review
- AI-assisted six-dimensional CT imaging for joint instability assessment.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- Deep learning reconstruction enhances tophus detection in a dual-energy CT phantom study.Scientific reports · 2025Article
- Systematic Review on Learning-based Spectral CT.ArXiv · 2024Article
- Image-domain material decomposition for dual-energy CT using unsupervised learning with data-fidelity loss.Medical physics · 2024Article
- What to Expect (and What Not) from Dual-Energy CT Imaging Now and in the Future?Journal of imaging · 2024Review
- Enhancing diagnostic accuracy of multiple myeloma through ML-driven analysis of hematological slides: new dataset and identification model to support hematologists.Scientific reports · 2024Article
- Systematic Review on Learning-based Spectral CT.IEEE transactions on radiation and plasma medical sciences · 2024Article
- Imaging of Multiple Myeloma: Present and Future.Journal of clinical medicine · 2024Review
- Recent advances in imaging and artificial intelligence (AI) for quantitative assessment of multiple myeloma.American journal of nuclear medicine and molecular imaging · 2024Review
- The evolution and current situation in the application of dual-energy computed tomography: a bibliometric study.Quantitative imaging in medicine and surgery · 2023Article
- [A semi-supervised material quantitative intelligent imaging algorithm for spectral CT based on prior information perception learning].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2023Article
- Multi-energy CT material decomposition using Bayesian deep convolutional neural network with explicit penalty of uncertainty and bias.Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
backgroundDual-energy CT with virtual noncalcium (VNCa) images allows the evaluation of focal intramedullary bone marrow involvement in patients with multiple myeloma. However, current commercial VNCa techniques suffer from excessive image noise and artifacts due to material decomposition used in synthesizing VNCa images.
objectivesIn this work, we aim to improve VNCa image quality for the assessment of focal multiple myeloma, using an Artificial intelligence based Generalizable Algorithm for mulTi-Energy CT (AGATE) method. MATERIALS AND
methodsAGATE method used a custom dual-task convolutional neural network (CNN) that concurrently carries out material classification and quantification. The material classification task provided an auxiliary regularization to the material quantification task. CNN parameters were optimized using custom loss functions that involved cross-entropy, physics-informed constraints, structural redundancy in spectral and material images, and texture information in spectral images. For training data, CT phantoms (diameters 30 to 45 cm) with tissue-mimicking inserts were scanned on a third generation dual-source CT system. Scans were performed at routine dose and half of the routine dose. Small image patches (i.e., 40 × 40 pixels) of tissue-mimicking inserts with known basis material densities were extracted for training samples. Numerically simulated insert materials with various shapes increased diversity of training samples. Generalizability of AGATE was evaluated using CT images from phantoms and patients. In phantoms, material decomposition accuracy was estimated using mean-absolute-percent-error (MAPE), using physical inserts that were not used during the training. Noise power spectrum (NPS) and modulation transfer function (MTF) were compared across phantom sizes and radiation dose levels. Five patients with multiple myeloma underwent dual-energy CT, with VNCa images generated using a commercial method and AGATE. Two fellowship-trained musculoskeletal radiologists reviewed the VNCa images (commercial and AGATE) side-by-side using a dual-monitor display, blinded to VNCa type, rating the image quality for focal multiple myeloma lesion visualization using a 5-level Likert comparison scale (-2 = worse visualization and diagnostic confidence, -1 = worse visualization but equivalent diagnostic confidence, 0 = equivalent visualization and diagnostic confidence, 1 = improved visualization but equivalent diagnostic confidence, 2 = improved visualization and diagnostic confidence). A post hoc assignment of comparison ratings was performed to rank AGATE images in comparison to commercial ones.
resultsAGATE demonstrated consistent material quantification accuracy across phantom sizes and radiation dose levels, with MAPE ranging from 0.7% to 4.4% across all testing materials. Compared to commercial VNCa images, the AGATE-synthesized VNCa images yielded considerably lower image noise (50-77% noise reduction) without compromising noise texture or spatial resolution across different phantom sizes and two radiation doses. AGATE VNCa images had markedly reduced area under NPS curves and maintained NPS peak frequency (0.7 lp/cm to 1.0 lp/cm), with similar MTF curves (50% MTF at 3.0 lp/cm). In patients, AGATE demonstrated reduced image noise and artifacts with improved delineation of focal multiple myeloma lesions (all readers comparison scores indicating improved overall diagnostic image quality [scores 1 or 2]).
conclusionsAGATE demonstrated reduced noise and artifacts in VNCa images and ability to improve visualization of bone marrow lesions for assessing multiple myeloma.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.