Evidence map›Paper›PMID 35983493›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering

Initial evaluation of 2D and 3D simulated high-speed 1000 fps vascular contrast-flow image sequences using computational fluid dynamics (CFD).

A Shields, K Williams, S S Veeturi, V Tutino, C Ionita, D R Bednarek, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

A ShieldsCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
K WilliamsCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
S S VeeturiCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
V TutinoCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
C IonitaCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
D R BednarekCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
S RudinCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.

Funding

High Speed Angiography at 1000 frames per secondR01EB030092 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB030092
6 · The paper itself

Abstract

Digital subtraction angiography (DSA) remains the clinical standard for detailed visualization of the neurovasculature due to its high-spatial resolution; however, detailed blood-flow quantification is impaired by its low-temporal resolution. Advances in photon-counting detector technology have led us to develop High-Speed Angiography (HSA), where x-ray images are acquired at 1000 fps for more accurate visualization and quantification of blood flow. We have implemented a physics-based optical flow method to extract such information from HSA, but validation of the angiography-derived velocity distributions is not straightforward. Computational fluid dynamics (CFD) is widely regarded as the benchmark for hemodynamic analysis, as it provides a multitude of quantitative flow parameters throughout the volume of interest. However, there are several limitations with this method related to over-simplification of boundary conditions and suboptimal meshing (spatial resolution), that make CFD simulation results an inexact criterion for validation. To overcome this issue for HSA validation, CFD was used to generate both simulated high-speed angiograms and the corresponding ground-truth 3D flow fields to better understand the relationship between the 3D volumetric-flow distribution and the 2D projected-flow distribution as is obtained with angiography, and the subsequent 2D approximation of flow velocity. Several geometries were investigated, ranging from simple pipe models to complex patient-specific aneurysms. Simulated datasets were analyzed with the optical flow algorithm, and the effects of flow divergence, quantum mottle, and intensity gradient on the calculation were evaluated. From these simulations, we can evaluate whether flow fields reconstructed from HSA are representative of significant flow patterns in the 3D vasculature.

Indexed as

Computational Fluid DynamicsHemodynamicsHigh-Speed AngiographyInterventional RadiologyPhoton-Counting Detectors

Identifiers

PMID35983493
PMCPMC9385176

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.