ArticleProceedings of SPIE--the International Society for Optical Engineering
Initial evaluation of 2D and 3D simulated high-speed 1000 fps vascular contrast-flow image sequences using computational fluid dynamics (CFD).
Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Investigating Angiographic Injection Parameters for Cerebral Aneurysm Hemodynamic Characterization Using Patient-Specific Simulated Angiograms.Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Digital subtraction angiography (DSA) remains the clinical standard for detailed visualization of the neurovasculature due to its high-spatial resolution; however, detailed blood-flow quantification is impaired by its low-temporal resolution. Advances in photon-counting detector technology have led us to develop High-Speed Angiography (HSA), where x-ray images are acquired at 1000 fps for more accurate visualization and quantification of blood flow. We have implemented a physics-based optical flow method to extract such information from HSA, but validation of the angiography-derived velocity distributions is not straightforward. Computational fluid dynamics (CFD) is widely regarded as the benchmark for hemodynamic analysis, as it provides a multitude of quantitative flow parameters throughout the volume of interest. However, there are several limitations with this method related to over-simplification of boundary conditions and suboptimal meshing (spatial resolution), that make CFD simulation results an inexact criterion for validation. To overcome this issue for HSA validation, CFD was used to generate both simulated high-speed angiograms and the corresponding ground-truth 3D flow fields to better understand the relationship between the 3D volumetric-flow distribution and the 2D projected-flow distribution as is obtained with angiography, and the subsequent 2D approximation of flow velocity. Several geometries were investigated, ranging from simple pipe models to complex patient-specific aneurysms. Simulated datasets were analyzed with the optical flow algorithm, and the effects of flow divergence, quantum mottle, and intensity gradient on the calculation were evaluated. From these simulations, we can evaluate whether flow fields reconstructed from HSA are representative of significant flow patterns in the 3D vasculature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.