Evidence map›Paper›PMID 35983349›Full record

ArticleRadiologia brasileira

Uterine artery embolization with highly compressible calibrated microspheres for the treatment of uterine fibroids.

Denis Szejnfeld, Rômulo Florêncio Tristão Santos, Antonio Massamitsu Kambara, Marcelo Bueno de Oliveira Colli, Felipe Nasser, Mauricio de Sena Martins, Suzan Menasce Goldman

Open access · diamondAbstract read
In one paragraph

Article in Radiologia brasileira. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Update on Endovascular Therapy for Fibroids and Adenomyosis.Seminars in interventional radiology · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Denis SzejnfeldEscola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.ORCID 0000-0001-8482-5955
Rômulo Florêncio Tristão SantosEscola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.ORCID 0000-0002-8679-7369
Antonio Massamitsu KambaraInstituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil.ORCID 0000-0001-6551-1942
Marcelo Bueno de Oliveira ColliInstituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil.ORCID 0000-0002-6524-8176
Felipe NasserHospital Santa Marcelina, São Paulo, SP, Brazil.ORCID 0000-0001-6682-2259
Mauricio de Sena MartinsHospital Maternidade Leonor Mendes de Barros, São Paulo, SP, Brazil.ORCID 0000-0001-8762-9204
Suzan Menasce GoldmanEscola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.ORCID 0000-0002-3596-3419
Universidade Federal de São Paulo · BRInstituto Dante Pazzanese de Cardiologia · BRHospital Geral de Bonsucesso · BRHospital Israelita Albert Einstein · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To evaluate the safety and efficacy of using highly compressible calibrated microspheres in uterine artery embolization (UAE) for the treatment of uterine fibroids. Materials and Methods: This was a prospective multicenter study. Thirty-two women with symptomatic uterine fibroids were selected for UAE between January 2019 and March 2020. The participants completed the Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaire, underwent contrast-enhanced pelvic magnetic resonance imaging (MRI), and were submitted to anti-Müllerian hormone measurement, subsequently undergoing UAE with Embosoft microspheres. After six months, the patients again completed the UFS-QOL questionnaire and underwent pelvic MRI. Results: The most common symptoms were abnormal uterine bleeding (in 81.3% of the cases), pelvic pain (in 81.3%), and compression (in 46.9%). Of the 32 patients evaluated, 12 (37.5%) had anemia due to abnormal uterine bleeding. Thirty patients completed the study. Among those patients, we observed median reductions of 21.4% in uterine volume and 15.9% in dominant fibroid volume. We identified no adverse events that could be attributed to the material itself, although there were events attributed to the UAE procedure in general. Conclusion: For the treatment of uterine fibroids, UAE using Embosoft microspheres shows satisfactory results, providing reductions in uterine and dominant fibroid volumes, with a low rate of adverse events, and improving patient quality of life, as well as demonstrating safety and efficacy.

Indexed as

LeiomyomaMicrospheresUterine arteryUterine artery embolization

Identifiers

PMID35983349
PMCPMC9380609
OpenAlexW4225288401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.