ArticleProceedings of SPIE--the International Society for Optical Engineering
Initial investigations of scatter cross-talk in simultaneous biplane high-speed 1000 frames per second neuro-angiography using Monte Carlo simulations.
Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept.Physics in medicine and biology · 2023Article
- Multi-angled simultaneous biplane High-Speed Angiography (HSA) of patient-specific 3D-printed aneurysm phantoms using 1000 fps CdTe Photon-Counting Detectors (PCD's).Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
The Aries photon counting detector (PCD) by Direct Conversion Inc. can image up to 1000 frames per second and is used to track contrast bolus in neuro-vasculature for hemodynamic calculations. For 3D tracking, synchronized biplane imaging with 1 ms acquisition times is used such that both imaging planes are exposed simultaneously. This leads to cross-scattered radiation being detected and a degradation of image quality compared to single-plane imaging. In this study, we utilize Monte Carlo (MC) methods to quantify the increase in scatter due to cross-talk without the use of a radiographic grid. EGSnrc biplane simulations were performed with the Zubal anthropomorphic head phantom. The total scatter plus primary and cross-scatter was calculated in the imaging planes for two orthogonal AP and lateral beams with a field size consistent with the 7.5×5 cm Aries detector, while the primary was determined with a 1×1 mm beam. The forward scatter was then determined from the difference between total and primary. The scatter is seen to increase by 4%-56% for AP projections and 48%-71% for lateral projections depending on detector orientation during simultaneous exposure. Scatter degradation from cross-talk can be reduced using an anti-scatter grid as well as the energy thresholding capabilities of the Aries PCD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.