ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2023
Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Real-world use of the pEGASUS-HPC stent in cerebral aneurysms: results from a multicenter retrospective series.Neuroradiology · 2026Observational
- Early clinical experience with the ACCEROInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Y-stent-assisted coiling with pEGASUS stents for intracranial bifurcation aneurysms: A multi-center retrospective study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Initial Experience with a New Self-Expanding Open-Cell Stent System with Antithrombotic Hydrophilic Polymer Coating (pEGASUS Stent) in the Treatment of Wide-Necked Intracranial Aneurysms.Neurointervention · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeLittle data exists on endovascular treatment of complex intracranial aneurysms with the Acandis Acclino low-profile self-expanding closed-cell stent systems and is mainly limited to short- or midterm results. We report our long-term, single-centre experience with three generations of Acclino stents treating complex intracranial aneurysms.
methods62 wide-necked intracranial aneurysms were treated electively using 88 Acclino stent systems. Single stent-assisted coiling was the preferred treatment in 38 cases and the kissing-Y stenting technique in 24 cases. We analysed demographic data and long-term follow-up results.
resultsAll stents were successfully deployed with immediate complete (Raymond Roy occlusion classification, RROC I) or near-complete occlusion (RROC II) achieved in 93,5%. Follow-up was available in 55 cases with a mean follow-up of 36 months (range 9-80 months). Long-term RROC I or II was achieved in 49 cases (89,1%). Three cases of stable residual aneurysmal filling were observed (5,5%). Seven aneurysms (12,7%) demonstrated a worsening on follow-up leading either to a neck remnant (4 cases, 7,3%) or to an aneurysm recurrence (3 cases, 5,5%). One recurrent aneurysm was retreated with coilembolization (1,8%). The directly procedural-related complication rate was 4,8%. Seven cases of clinically silent in-stent stenosis (12,7%; morbidity n = 0) were detected on long-term follow-up, six of them using the kissing-Y stenting technique.
conclusionEndovascular treatment of various intracranial aneurysms using the Acandis Acclino stent systems is safe and efficient with high aneurysm occlusion rates combined with low complication rates on long-term follow-up. Overall, rates of in-stent stenosis are low but may depend on the treatment technique (single stent-assisted coiling versus kissing-Y stenting with coiling).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.