ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2022
In Vivo Aberration Correction for Transcutaneous HIFU Therapy Using a Multielement Array.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Prospects for clinical translation of histotripsy in liver applications: a systematic review based on preclinical studies.Quantitative imaging in medicine and surgery · 2026Review
- Aberration correction expands the treatment envelope for histotripsy in the liver.Physics in medicine and biology · 2025Article
- Doppler-based assessment of boiling histotripsy-induced volumetric tissue liquefaction in vivo.Ultrasonics · 2025Article
- A Fully Populated Transrectal Array for Boiling Histotripsy Ablation of the Prostate.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025Article
- Review
- Respiratory Motion Effects and Mitigation Strategies on Boiling Histotripsy in Porcine Liver and Kidney.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025Article
- In Vivo Cavitation-Based Aberration Correction of Histotripsy in Porcine Liver.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024Article
- Histotripsy: A Method for Mechanical Tissue Ablation with Ultrasound.Annual review of biomedical engineering · 2024Review
- Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024Article
- Soft Tissue Aberration Correction for Histotripsy Using Acoustic Emissions From Cavitation Cloud Nucleation and Collapse.Ultrasound in medicine & biology · 2023Article
- Clinical translation of abdominal histotripsy: a review of preclinical studies in large animal models.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023Review
- The histotripsy spectrum: differences and similarities in techniques and instrumentation.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023Review
- Aberration correction in abdominal histotripsy.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023Review
- Mechanical damage thresholds for hematomas near gas-containing bodies in pulsed HIFU fields.Physics in medicine and biology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
One of the challenges of transcutaneous high-intensity focused ultrasound (HIFU) therapies, especially ones relying heavily on shock formation, such as boiling histotripsy (BH), is the loss of focusing from aberration induced by the heterogeneities of the body wall. Here, a methodology to execute aberration correction in vivo is proposed. A custom BH system consisting of a 1.5-MHz phased array of 256 elements connected to a Verasonics V1 system is used in pulse/echo mode on a porcine model under general anesthesia. Estimation of the time shifts needed to correct for aberration in the liver and kidney is done by maximizing the value of the coherence factor on the acquired backscattered signals. As this process requires multiple pulse/echo sequences on a moving target to converge to a solution, tracking is also implemented to ensure that the same target is used between each iteration. The method was validated by comparing the acoustic power needed to generate a boiling bubble at one target with aberration correction and at another target within a 5-mm radius without aberration correction. Results show that the aberration correction effectively lowers the acoustic power required to reach boiling by up to 45%, confirming that it indeed restored formation of the nonlinear shock front at the focus.