ArticleAnalytical chemistry2022
Intradermal Glycine Detection with a Wearable Microneedle Biosensor: The First In Vivo Assay.
Article in Analytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 39 citations in OpenAlex.
- Minimally Invasive and in Situ Capacitive Sensing of Cardiac Troponin I from Interstitial Fluid.ACS sensors · 2025Article
- Monomeric Glycine oxidase from Azotobacter vinelandii for Glycine biosensing.World journal of microbiology & biotechnology · 2025Article
- Visualizing intracellular glycine with two-dye and single-dye ratiometric RNA-based sensors.Nucleic acids research · 2025Article
- From mechanism to applications: Advanced microneedles for clinical medicine.Bioactive materials · 2025Review
- Article
- Needle-Shaped Biosensors for Precision Diagnoses: From Benchtop Development to In Vitro and In Vivo Applications.Biosensors · 2024Review
- Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy.ACS sensors · 2024Article
- Advances in microneedles for transdermal diagnostics and sensing applications.Mikrochimica acta · 2024Review
- SERS-Based Microneedle Biosensor for In Situ and Sensitive Detection of Tyrosinase.Biosensors · 2024Article
- Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal COACS sensors · 2024Article
- Epidermal Wearable Biosensors for the Continuous Monitoring of Biomarkers of Chronic Disease in Interstitial Fluid.Micromachines · 2023Review
- In Vivo Transdermal Multi-Ion Monitoring with a Potentiometric Microneedle-Based Sensor Patch.ACS sensors · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Glycine (GLY) is gaining importance in medical diagnoses due to its relationship with multiple physiological functions. Today, GLY is exclusively analyzed using instrumentation centralized in clinical labs, and a tangible point-of-care tool that gathers real-time data from the patient for effective and fast evaluations is lacking. Relevant clinical advances are expected as soon as the rapid provision of both punctual and continuous measurements is possible. In that context, this work presents a microneedle (MN)-based biosensor for intradermal GLY detection in interstitial fluid (ISF). The MN tip is externally tailored to detect GLY levels through the hydrogen peroxide formed in its reaction with a quinoprotein-based GLY oxidase enzyme. The analytical performance of the MN biosensor indicates a fast response time (<7 s); acceptable reversibility, reproducibility, and stability; as well as a wide linear range of response (25-600 μM) that covers the physiological levels of GLY in ISF. The MN biosensor conveniently exhibits high selectivity for GLY over other compounds commonly found in ISF, and the response is not influenced by temperature, pH, or skin insertions. Validated intradermal measurements of GLY were obtained at the in vitro (with pieces of rat skin), ex vivo (on-body tests of euthanized rats) and in vivo (on-body tests of anesthetized rats) levels, demonstrating its ability to produce accurate physiological data. The developed GLY MN biosensor is skin-wearable and provides reliable, real-time intradermal GLY measurements in ISF by means of a minimally invasive approach.
Indexed as
Identifiers
What OpenQuestion holds