Evidence map›Paper›PMID 35979792›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2022

[Three-dimensional finite element analysis of exo-cortical placement of humeral calcar screw for reconstruction of medial column stability].

Bo Li, Shimin Chang, Sunjun Hu, Shouchao Du, Wenfeng Xiong

Open access · greenAbstract readCase Reports
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Bo LiDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Shimin ChangDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Sunjun HuDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Shouchao DuDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Wenfeng XiongDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Yangpu Hospital of Tongji University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To explore the biomechanical stability of the medial column reconstructed with the exo-cortical placement of humeral calcar screw by three-dimensional finite element analysis. Methods: A 70-year-old female volunteer was selected for CT scan of the proximal humerus, and a wedge osteotomy was performed 5 mm medially inferior to the humeral head to form a three-dimensional finite element model of a 5 mm defect in the medial cortex. Then, the proximal humeral locking plate (PHILOS) was placed. According to distribution of 2 calcar screws, the study were divided into 3 groups: group A, in which 2 calcar screws were inserted into the lower quadrant of the humeral head in the normal direction for supporting the humeral head; group B, in which 1 calcar screw was inserted outside the cortex below the humeral head, and the other was inserted into the humeral head in the normal direction; group C, in which 2 calcar screws were inserted outside the cortex below the humeral head. The models were loaded with axial, shear, and rotational loadings, and the biomechanical stability of the 3 groups was compared by evaluating the peak von mises stress (PVMS) of the proximal humerus and the internal fixator, proximal humeral displacement, neck-shaft angle changes, and the rotational stability of the proximal humerus. Seven cases of proximal humeral fractures with comminuted medial cortex were retrospectively analyzed between January 2017 and December 2020. Locking proximal humeral plate surgery was performed, and one (5 cases) or two (2 cases) calcar screws were inserted into the inferior cortex of the humeral head during the operation, and the effectiveness was observed. Results: Under axial and shear force, the PVMS of the proximal humerus in group B and group C was greater than that in group A, the PVMS of the internal fixator in group B and group C was less than that in group A, while the PVMS of the proximal humerus and internal fixator between group B and group C were similar. The displacement of the proximal humerus and the neck-shaft angle change among the 3 groups were similar under axial and shear force, respectively. Under the rotational torque, compared with group A, the rotation angle of humerus in group B and group C increased slightly, and the rotation stability decreased slightly. All the 7 patients were followed up 6-12 months. All the fractures healed, and the healing time was 8-14 weeks, with an average of 10.9 weeks; the neck-shaft angle changes (the difference between the last follow-up and the immediate postoperative neck-shaft angle) was (1.30±0.42)°, and the Constant score of shoulder joint function was 87.4±4.2; there was no complication such as humeral head varus collapse and screw penetrating the articular surface. Conclusion: For proximal humeral fractures with comminuted medial cortex, exo-cortical placement of 1 or 2 humeral calcar screw of the locking plate outside the inferior cortex of the humeral head can also effectively reconstruct medial column stability, providing an alternative approach for clinical practice.

Indexed as

Fractures, ComminutedShoulder FracturesAgedBone PlatesBone ScrewsFemaleFinite Element AnalysisFracture Fixation, InternalHumansHumeral HeadRetrospective Studiescalcar screwexo-cortical buttressmedial column reconstructionProximal humerus fracturethree-dimensional finite element analysis

Identifiers

PMID35979792
PMCPMC9379462
OpenAlexW4298198136

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.