Evidence map›Paper›PMID 35979002›Full record

ArticleEvidence-based complementary and alternative medicine : eCAM2022

Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation.

Cheng Cheng, Banglong Xu, Jianlong Sheng, Zheng Huang, Fei He, Feng Gao, Xiaochen Wang

Open access · hybridAbstract read
In one paragraph

Article in Evidence-based complementary and alternative medicine : eCAM, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Cheng ChengDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Banglong XuDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Jianlong ShengDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Zheng HuangDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Fei HeDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Feng GaoDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.
Xiaochen WangDepartment of Cardiology, The Second Hospital of Anhui Medical University, Furong Road 678, Hefei, Anhui 230601, China.ORCID https://orcid.org/0000-0003-2901-2075
Anhui Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). Methods: We retrospectively analyzed a total of 72 patients who were admitted with paroxysmal AF, and who underwent radiofrequency catheter ablation (RFCA) for the first time. Of these patients, 36 cases underwent low-power, long-duration (LPLD, (30-35 W/20-40 s) pulmonary vein isolation (PVI) delivered by an SmartTouch (ST) catheter (control group), and the other 36 cases underwent high-power, short-duration (HPSD, (45-50 W/10-20 s) PVI delivered by a STSF catheter (study group). The baseline data, duration of PVI, procedural time, fluoroscopy time, the rate of first-pass isolation, irrigation perfusion, eschar and steam pop occurrences, intraoperative complications, and the rate of stable sinus rhythm maintenance following a blanking period of three months were analyzed between the two groups. Results: The isolation time of bilateral PVI and procedural time in the study group were markedly less than in controls ( Conclusions: The HPSD strategy delivered by the STSF catheter was superior to conventional LPLD ablation through the ST catheter with respect to efficiency, acute procedural effectiveness, short-term safety, and the risk of heart failure in patients with paroxysmal AF.

Identifiers

PMID35979002
PMCPMC9377865
OpenAlexW4290697820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.