Phantom-based acquisition time and image reconstruction parameter optimisation for oncologic FDG PET/CT examinations using a digital system.
Article in BMC cancer, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 17 citations in OpenAlex.
- Toward an optimized PET reconstruction protocol for spinal cord: superiority of OSEM with TOF and PSF.EJNMMI physics · 2026Article
- Optimizing acquisition time and injected dose inBMC medical informatics and decision making · 2026Article
- Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learning.EJNMMI physics · 2026Article
- Development of lesion and organ negative cast modelling technique for quality assurance and optimization of nuclear medicine images.Communications medicine · 2025Article
- Practical use of radiomic features as a metric for image quality discrimination in [EJNMMI reports · 2025Article
- External phantom-based validation of a deep-learning network trained for upscaling of digital low count PET data.EJNMMI physics · 2025Article
- Staging of prostate Cancer with ultra-fast PSMA-PET scans enhanced by AI.European journal of nuclear medicine and molecular imaging · 2025Article
- Detection and quantification of small and low-uptake lesions for differentiated thyroid carcinoma using non-time-of-flight iodine-124 PET/MRI.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 2 countries.
Funding
Abstract
backgroundNew-generation silicon-photomultiplier (SiPM)-based PET/CT systems exhibit an improved lesion detectability and image quality due to a higher detector sensitivity. Consequently, the acquisition time can be reduced while maintaining diagnostic quality. The aim of this study was to determine the lowest
methodsThree phantoms were used: a soft-tissue tumour phantom, a bone-lung tumour phantom, and a resolution phantom. Phantom conditions (lesion sizes from 6.5 mm to 28.8 mm in diameter, lesion activity concentration of 15 kBq/mL, and signal-to-background ratio of 5:1) were derived from patient data. PET data were acquired on an SiPM-based Biograph Vision PET/CT system for 10 min in list-mode format and resampled into time frames from 30 to 300 s in 30-s increments to simulate different acquisition times. Different image reconstructions with varying iterations, voxel sizes, and Gaussian filters were probed. Contrast-to-noise-ratio (CNR), maximum, and peak signal were evaluated using the 10-min acquisition time image as reference. A threshold CNR value ≥ 5 and a maximum (peak) deviation of ± 20% were considered acceptable. 20 patient data sets were evaluated regarding lesion quantification as well as agreement and correlation between reduced and full acquisition time standard uptake values (assessed by Pearson correlation coefficient, intraclass correlation coefficient, Bland-Altman analyses, and Krippendorff's alpha).
resultsAn acquisition time of 60 s per bed position yielded acceptable detectability and quantification results for clinically relevant phantom lesions ≥ 9.7 mm in diameter using OSEM-TOF or OSEM-TOF+PSF image reconstruction, a 4-mm Gaussian filter, and a 1.65 × 1.65 x 2.00-mm
conclusionA threefold reduction in acquisition time is possible. Patients might benefit from more comfortable examinations or reduced radiation exposure, if instead of the acquisition time the applied activity is reduced.