Evidence map›Paper›PMID 35977529›Full record

ArticleCardiology2022

Feasibility, Efficiency, and Safety of Zero-Fluoroscopy Catheter Interventions for Right-Sided Cardiac Arrhythmias Using Only Electroanatomic Mapping.

Daniel Hofer, Jan Steffel, Firat Duru, Vera Graup, Tom Sasse, Ardan Saguner, Alexander Breitenstein

Open access · hybridAbstract read
In one paragraph

Article in Cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Daniel HoferDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Jan SteffelDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Firat DuruDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Vera GraupDivision of General Internal Medicine, Triemli Hospital, Zurich, Switzerland.
Tom SasseDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Ardan SagunerDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Alexander BreitensteinDivision of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
University Hospital of Zurich · CHTriemli Hospital · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFluoroscopy is traditionally used for catheter interventions in electrophysiology but carries a long-term health risk. Besides additional invasive procedures to achieve zero-fluoroscopy (ZF) interventions, electroanatomic mapping may be an alternative to fluoroscopy without the need of additional procedures. We aimed to investigate the feasibility, safety, and efficiency of a ZF approach using only electroanatomic mapping (ZF) compared to a conventional fluoroscopic (CF) approach for patients with right sided cardiac arrhythmias.

methodsWe performed a single centre retrospective cohort study of consecutive patients undergoing catheter interventions for electrophysiologic procedures from January 2019 to December 2020. Patients with left-sided arrhythmias, focal cryoablation, implanted endocardial devices, or additional interventions requiring fluoroscopy were excluded.

results202 patients underwent a ZF and 126 patients underwent a CF approach for right-sided cardiac arrhythmias. Apart from atrial fibrillation (ZF 16% vs. CF 9%, p = 0.044), baseline demographics were similar in both groups. Acute success rate was 100% in the ZF group and 97.9% in the CF group. Mean procedure time was lower in the ZF group (70 ± 36 vs. 87 ± 44 min, p = 0.0001), while ablation time (356 ± 324 vs. 320 ± 294 s, p = 0.157) was similar. Total complication rate was low in general (1.0 % major, 2% minor complications) and without a difference between both groups.

conclusionA ZF approach using only electroanatomic mapping without additional invasive procedures to diagnose and treat right-sided cardiac arrhythmias is feasible, efficient, and safe.

Indexed as

Atrial FibrillationCatheter AblationCathetersElectrophysiologic Techniques, CardiacFeasibility StudiesFluoroscopyHumansRetrospective StudiesTreatment OutcomeAblationElectroanatomic mappingElectrophysiologyFluoroscopyZero-fluoro

Identifiers

PMID35977529
PMCPMC9808658
OpenAlexW4292148855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.