ArticleTranslational vision science & technology2022
A Novel Microsurgical Robot: Preliminary Feasibility Test in Ophthalmic Field.
Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.
- Evaluating the Clinical Utility of Robotic Systems in Plastic and Reconstructive Surgery: A Systematic Review.Sensors (Basel, Switzerland) · 2025Pooled it
- Robot-Assisted Eye Surgery: A Systematic Review of Effectiveness, Safety, and Practicality in Clinical Settings.Translational vision science & technology · 2024Pooled it
- Performance of a prototype electric silicone oil injector and aspirator in vitreoretinal surgery.Frontiers in medicine · 2026Article
- Learning curve of robotic assisted microsurgery in surgeons with different skill levels: a prospective preclinical study.Journal of robotic surgery · 2024Article
- Ideal suturing technique for robot-assisted microsurgical anastomoses.Journal of robotic surgery · 2024Article
- Preclinical Performance of the Combined Application of Two Robotic Systems in Microsurgery: A Two-center Study.Plastic and reconstructive surgery. Global open · 2024Article
- A technical feasibility study on adaptation of a microsurgical robotic system to an intraoperative complication management in dental implantology: perforated Schneiderian membrane repair using SymaniJournal of robotic surgery · 2023Article
- Microsurgery Robots: Applications, Design, and Development.Sensors (Basel, Switzerland) · 2023Review
- Article
- Artificial Intelligence in Ophthalmic Surgery: Current Applications and Expectations.Clinical ophthalmology (Auckland, N.Z.) · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This study investigated the feasibility and potential advantage of using a new microsurgical teleoperated robot, Symani Surgical System, in the ophthalmology field. In particular, considering the extreme precision of the system and the dexterity of the instrument, possible use of the Symani Surgical System has been explored for suturing in corneal graft surgery. Methods: Manual and robot-assisted suturing of partial corneal transplants was performed on the porcine eye model by an ophthalmologist with experience with the porcine model. Suturing execution time, suture placement, and tomographic parameters were analyzed to assess the regularity and distribution of corneal sutures for both manual and robotic treatment. Results: The two robot-assisted procedures were properly completed on the porcine model, confirming the ease of use of the system and its capabilities, as well as the dexterity of the microinstruments. Manual and robotic treatments were found to be equivalent in terms of distance and angular precision of suture placement and corneal surface regularity (Gaussian anterior curvature). The robotic procedure required longer suturing execution times compared with the manual procedure. Conclusions: The technical and clinical feasibility of robot-assisted suturing of partial corneal graft using the Symani Surgical System has been confirmed for the first time, to our knowledge, using an ex vivo porcine model. Robotic suturing required longer time to complete but was equivalent to the manual procedure with regard to the imaging data collected. Translational Relevance: This study evaluated the use of the Symani Surgical System in the ophthalmology field. Future investigations could further identify the advantages offered by the stability, dexterity, and motion precision of the system for corneal surgeries, paving the way for clinical use in both adult and even more challenging pediatric therapy.
Indexed as