ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2023
Locking in trochanteric fractures: a comparison of static versus dynamic locking using the Gamma3 nail.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Development of early complications after treatment of trochanteric fractures with an intramedullary sliding hip screw in a geriatric population.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- [Research progress on distal interlocking screws of cephalomedullary nails in intertrochanteric fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- Biomechanical Behavior of Dynamic vs. Static Distal Locking Intramedullary Nails in Subtrochanteric Femur Fractures.Bioengineering (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe Gamma3 nail (Stryker®) is an intramedullary device consisting of a proximal lag screw and distal interlocking screw. It is still unknown whether the screw locking mode could influence clinical outcomes. The aim of this study is to compare static and dynamic screw locking regarding their influence on surgical revisions and lag screw displacement.
methodsA retrospective single-centre study was performed on patients ≥ 60 years admitted for a trochanteric fracture between September 2016 and January 2020. Surgical revisions and lag screw displacement were evaluated at 6 weeks and 1-year follow-up, respectively.
resultsA total of 142 patients were included for analysis. Surgical revisions were needed in 13 cases (9.2%). Indications included implant breakage (n = 3), lag screw cut-out (n = 3), lateral hip pain (n = 6) and non-union (n = 1). The number of surgical revisions was not different between static and dynamic locking (OR 2.55; 95%CI 0.73-8.56; p 0.142). The median lag screw displacement was 2.5 mm, which was similar for static and dynamic locking (2.3 mm versus 2.7 mm; p 0.785).
conclusionThe screw locking mode of the Gamma3 nail is not associated with a higher risk of surgical revisions. However, the design of the Gamma3 nail may not be suitable for static locking.
Indexed as
Identifiers
35976574What OpenQuestion holds
Registered trials