ArticleClinical ophthalmology (Auckland, N.Z.)2022
Refractive and Visual Outcomes of a Monofocal Non-Constant Aberration Aspheric Intraocular Lens.
Article in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Clinical Outcomes of a Monofocal, Optimized, Aspheric IOL in Eyes with Different Degrees of Corneal Spherical Aberration.Clinical ophthalmology (Auckland, N.Z.) · 2026Trial
- Capsular bag performance of an aspheric hydrophobic IOL after conventional phacoemulsification or femtosecond laser-assisted cataract surgery: 12-month results of a randomized prospective study.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025Trial
- Clinical Outcomes of a Monofocal, Optimized, Aspheric, Hydrophobic Acrylic Intraocular Lens Implant.Clinical ophthalmology (Auckland, N.Z.) · 2023Trial
- Article
- Evaluation of visual outcomes, optical quality, and patient satisfaction with a novel monofocal intraocular lens.BMC ophthalmology · 2026Article
- Short-Term Visual and Optical Performance of the ZEISS CT LUCIA 621P Intraocular Lens Across Different Power Ranges.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Preliminary findings from a retrospective comparative study on a novel hydrophobic C-loop monofocal intraocular lens.Scientific reports · 2025Article
- Randomized controlled bilateral comparison of femtosecond laser-assisted cataract surgery versus conventional phacoemulsification.BMJ surgery, interventions, & health technologies · 2025Article
- Visual Outcomes of a New Hydrophobic Trifocal Intraocular Lens in Cataract Treatment: A Prospective Clinical Study.Journal of ophthalmology · 2025Article
- Visual and Refractive Outcomes of a New Monofocal, Non-Constant Aberration-Correcting Aspheric Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Comparison of Short-Term Clinical Outcomes After Implantation of Two Monofocal, Aspheric Intraocular Lenses.Diagnostics (Basel, Switzerland) · 2024Article
- Through-focus performance and off-axis effects in aspheric monofocal intraocular lenses.Biomedical optics express · 2024Article
- Early Clinical Experience with a New Hydrophobic Acrylic Single-Piece Monofocal Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- A comparative analysis of postoperative visual outcomes following cataract surgery with different brands of Monofocal Intraocular Lenses.Pakistan journal of medical sciencesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate the refractive and visual outcomes following cataract surgery and implantation of a new monofocal non-constant aberration aspheric intraocular lens (IOL). Methods: Ninety eyes of 86 patients who underwent implantation the CT LUCIA 621P IOL (Carl Zeiss Meditec AG) were retrospectively analyzed in this study. Main outcome measures were refractive error and monocular corrected distance visual acuity (CDVA) and monocular uncorrected distance visual acuity (UDVA) values. Patients were evaluated at 1-month post-surgery and intra- and post-operative complications were recorded. Results: Eighty percent of the eyes showed a CDVA of 20/25 or better before surgery. The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.64±0.22 and 0.89±0.13, respectively. All eyes showed the same or better difference between UDVA and CDVA. In relation to the postoperative spherical equivalent, the highest percentage of eyes, 31.11%, was for the range between -0.50 and -0.14D followed by 22.22% for the ±0.13D range. Ninety percent of the eyes were within ±1.00 D and 73.33% of eyes within ±0.50 D. The mean postoperative spherical equivalent was -0.18±0.55D. 37.78% and 76.67% of the eyes showed a value ≤0.50 D and ≤1.00D, respectively, being the mean postoperative refractive cylinder -0.81±0.50D. No adverse events were reported in whole sample intra and postoperatively. Conclusion: The present study shows that cataract surgery with an monofocal non-constant aberration aspheric IOL implantation resulted in good visual performance and refractive outcomes. This lens may be considered as a valid choice for patients in a standard-routine cataract surgery practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.