Evidence map›Paper›PMID 35974363›Full record

ArticleBMC musculoskeletal disorders2022

Blood titanium levels in patients with large and sliding titanium implants.

Martina Tognini, Harry Hothi, Stewart Tucker, Edel Broomfield, Masood Shafafy, Panos Gikas, Anna Di Laura, Johann Henckel, Alister Hart

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Martina TogniniInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK. martina.tognini.19@ucl.ac.uk.
Harry HothiInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
Stewart TuckerGreat Ormond Street Hospital for Children NHS Foundation Trust, London, UK.
Edel BroomfieldGreat Ormond Street Hospital for Children NHS Foundation Trust, London, UK.
Masood ShafafyDepartment of Trauma and Orthopaedics, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Panos GikasInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
Anna Di LauraInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
Johann HenckelInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
Alister HartInstitute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
University College London · GBGreat Ormond Street Hospital for Children NHS Foundation Trust · GBRoyal National Orthopaedic Hospital · GBNottingham University Hospitals NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTitanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips.

methodsThis study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism ("spine rods", n = 18), long bone tumour implants ("tumour implants", n = 13) and 3D-printed customised massive acetabular defect implants ("massive acetabular implants", n = 10). This data was compared with standard, uncemented primary titanium hip implants ("standard hips", 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups.

resultsThe median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6-4.9), 9.7 ppb (4.0-25.4), 2.6 ppb (0.4-104.4) and 5.7 ppb (1.6-31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001).

conclusionThis study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisChromiumCobaltHumansMetalsProsthesis DesignTitaniumChromiumCobaltMetalsTitaniumBloodImplantsTitanium

Identifiers

PMID35974363
PMCPMC9380337
OpenAlexW4293062718

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked