ArticleJournal of cardiovascular pharmacology and therapeutics
Understanding the Mechanism of Drug Transfer and Retention of Drug-Coated Balloons.
Article in Journal of cardiovascular pharmacology and therapeutics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.
- Comparative Outcomes of Drug-Eluting Stents Versus Drug-Eluting Balloons in Patients with Chronic Kidney Disease: A Systematic Review of Current Evidence.F1000Research · 2026Pooled it
- Paclitaxel distribution assessment after drug-coated balloon treatment in the superficial femoral artery: SNOW grade.Heart and vessels · 2026Article
- Paclitaxel- and Sirolimus-Coated Balloons Versus Drug-Eluting Stents in Coronary Artery Disease: A Comprehensive Narrative Review.Life (Basel, Switzerland) · 2025Review
- Drug-Coated Balloons for Coronary Artery Disease: From Theory to Practice.Current treatment options in cardiovascular medicine · 2025Article
- Consensus Statement on Drug-Coated Balloons in Coronary Artery Disease from the Cardiovascular Intervention Association of Thailand.Journal of clinical medicine · 2025Review
- Comparison of High-Dose versus Low-Dose Paclitaxel Drug-Coated Balloons for Native Femoropopliteal Artery Disease: An Analysis of the K-VIS ELLA Registry.Yonsei medical journal · 2025Article
- The Impact of Peripheral Vascular Motion on Acute Drug Retention of Intravascular Devices.Cardiovascular engineering and technology · 2025Article
- A Novel In Silico-Ex Vivo Model for Correlating Coating Transfer to Tissue with Local Drug-Coated Balloon-Vessel Contact Pressures.Annals of biomedical engineering · 2025Article
- Drug-coated balloons in percutaneous coronary interventions: existing evidence and emerging hopes.Cardiology journal · 2025Review
- In-culture coronary stenting in anFrontiers in cardiovascular medicine · 2025Article
- Peripheral Drug-Coated Balloon for Coronary Drug-Eluting Stent In-Stent Restenosis: Off-Label, Off-Target.Journal of the Society for Cardiovascular Angiography & Interventions · 2024Article
- Design and use of an ex vivo peripheral simulating bioreactor system for pharmacokinetic analysis of a drug coated stent.Bioengineering & translational medicine · 2024Article
- Pre-clinical investigation of liquid sirolimus for local drug delivery.Frontiers in cardiovascular medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveThe purpose of this study was to determine the impact of varying inflation parameters on paclitaxel delivery and retention using a commercially available DCB.
backgroundDrug-coated balloons (DCB) have become the standard treatment for peripheral artery disease. Clinical data suggest that varying DCB delivery parameters directly impact patient outcome. Differences in delivery parameters can potentially alter the retention of the drug coating on DCBs.
methodsHarvested porcine carotid arteries were utilized in an
resultsArterial paclitaxel levels were found to be less at an inflation ratio of 1:1 with 3-minute transit time as compared to 30 seconds of transit time at 1 hour (12.3 ± 1.6 ng/mg vs. 391 ± 139 ng/mg,
conclusionArterial paclitaxel retention is reduced with extended transit times and sub-optimal expansion of the balloon. Optimization of delivery parameters can serve as an effective strategy to enhance clinical DCB outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials