Evidence map›Paper›PMID 35968361›Full record

ArticleFrontiers in neuroscience2022

The CX-DZ-II intelligent electronic stimulator for neck pain caused by cervical spondylosis: A two-center, randomized, controlled, and non-inferiority trial.

Liping Chen, Dehua Li, Jing Xu, Hao Liang, Ya Zhang, Yulan Ren, Fanrong Liang

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Liping ChenCollege of Acupuncture Moxibustion and Tuina, Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Dehua LiHospital of Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Jing XuCollege of Acupuncture Moxibustion and Tuina, Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Hao LiangHospital of Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Ya ZhangCollege of Acupuncture Moxibustion and Tuina, Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Yulan RenCollege of Chinese Classics, Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Fanrong LiangCollege of Acupuncture Moxibustion and Tuina, Chengdu University of Traditional Chinese Medicine, Chengdu, China.
Chengdu University of Traditional Chinese Medicine · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Electroacupuncture (EA) has been commonly used for the management of neck pain caused by cervical spondylosis (NPCS); however, current electrical instruments have limitations on intelligence, digitalization, and visualization. The intelligent electronic stimulator (CX-DZ-II) is a digital device with an evidence-based diagnosis and treatment system. This study aimed to investigate the efficacy and safety of the CX-DZ-II intelligent EA instrument for NPCS. Materials and Methods: A total of 164 patients with NPCS [mean age (SD), 49.48 (13.47) years] were randomly assigned to receive 8 sessions (over 2 weeks) EA of the intelligent electronic stimulator (CX-DZ-II) or the regular electronic stimulator (SDZ-II). The primary outcome was the change of the visual analog scale (VAS) from baseline to 2 weeks of treatment. Secondary outcomes included mean scores of the VAS after each treatment in 1 week, responder rate, drug-usage rate of non-steroidal antipyretic analgesics (NSAAs), the occurrence rate of adverse events (AEs), proportions of apparatus with defect during treatment, and excellent rate of apparatus. Results: The intelligent electronic stimulator (CX-DZ-II) was non-inferior to the regular electronic stimulator (SDZ-II) for changes from baseline in the VAS [3.36 vs. 3.23, with a difference of 0.17 (95% CI, -0.36 to 0.69), Conclusion: The intelligent electronic stimulator (CX-DZ-II) was non-inferior to the regular electronic stimulator (SDZ-II) in relieving neck pain. The intelligent electronic stimulator (CX-DZ-II) is a promising non-inferior alternative instrument for NPCS. Clinical Trial Registration: [https://clinicaltrials.gov/], identifier [NCT030 05301].

Indexed as

cervical spondylosiselectroacupunctureneck painnon-inferiority trialrandomized controlled trial

Identifiers

PMID35968361
PMCPMC9366011
OpenAlexW4288074440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.