Evidence map›Paper›PMID 35966406›Full record

ArticleAnnals of medicine and surgery (2012)2022

The effect of plastic tape seal to reduce face seal leak in respirator N-95 type 1860.

Mirta Hediyati Reksodiputro, Harim Priyono, Luthfi Ari Wibowo, Jenny Bashiruddin, Ratna Dwi Restuti, Dini Widiarni Widodo, Dewi Sumaryani Soemarko, Joedo Prihartanto, Prasandhya Astagiri Yusuf

Abstract read
In one paragraph

Article in Annals of medicine and surgery (2012), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mirta Hediyati ReksodiputroDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Harim PriyonoDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Luthfi Ari WibowoDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Jenny BashiruddinDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Ratna Dwi RestutiDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Dini Widiarni WidodoDepartment of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Dewi Sumaryani SoemarkoDepartment of Community Medicine, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Joedo PrihartantoDepartment of Community Medicine, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
Prasandhya Astagiri YusufDepartment of Medical Physic, Faculty of Medicine Universitas Indonesia/Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The risk of face seal leak while using N-95 respirators is experienced by health workers and thus failing fit test are quite common. Finding solutions to overcome face seal leaks is crucial; one of which is by sealing the N-95 respirator. The seal used in this research was Tegaderm® a transparent film dressing or a plastic tape which is known to have the advantages of strong adhesion, high level of pore density and standardized medical grade. This study tries to determine the effectiveness of plastic tape adhesive on the N-95 type 1860 respirator in overcoming face seal leak qualitative fit test using Bitrex immediately after being worn and after 4 h of using it. The study used a quantitative approach with an incidence study design conducted pre and post experimental without comparison to see the effectiveness of plastic tape sealing. The subjects for the research were 81 health workers in the CMH environment who were at risk of being exposed to COVID-19. The study found a significant difference in the Bitrex fit test immediately after sealing the N-95 type 1860 respirator with plastic tape; 100% passed the fit test immediately after sealing, and 64.2% passed the fit test after 4 h of working. The effectiveness of sealing using plastic tape is considered to be quite good to overcome face seal leak on the N-95 type 1860 respirator. Health care workers need to be more vigilance to ensure better face seal.

Indexed as

Bitrex fit testN-95 respirator type 1860Plastic tapeRespirator leak

Identifiers

PMID35966406
PMCPMC9364724

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.