Evidence map›Paper›PMID 35965576›Full record

ReviewFrontiers in oncology2022

Considerations for Upright Particle Therapy Patient Positioning and Associated Image Guidance.

Lennart Volz, Yinxiangzi Sheng, Marco Durante, Christian Graeff

Abstract readReview
In one paragraph

Review in Frontiers in oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Modeling and Validation of a Proton Therapy Couch Top.International journal of particle therapy · 2025
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Calculation method for novel upright CT scanner isodose curves.Journal of applied clinical medical physics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lennart VolzBiophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.
Yinxiangzi ShengBiophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.
Marco DuranteBiophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.
Christian GraeffBiophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Particle therapy is a rapidly growing field in cancer therapy. Worldwide, over 100 centers are in operation, and more are currently in construction phase. The interest in particle therapy is founded in the superior target dose conformity and healthy tissue sparing achievable through the particles' inverse depth dose profile. This physical advantage is, however, opposed by increased complexity and cost of particle therapy facilities. Particle therapy, especially with heavier ions, requires large and costly equipment to accelerate the particles to the desired treatment energy and steer the beam to the patient. A significant portion of the cost for a treatment facility is attributed to the gantry, used to enable different beam angles around the patient for optimal healthy tissue sparing. Instead of a gantry, a rotating chair positioning system paired with a fixed horizontal beam line presents a suitable cost-efficient alternative. Chair systems have been used already at the advent of particle therapy, but were soon dismissed due to increased setup uncertainty associated with the upright position stemming from the lack of dedicated image guidance systems. Recently, treatment chairs gained renewed interest due to the improvement in beam delivery, commercial availability of vertical patient CT imaging and improved image guidance systems to mitigate the problem of anatomical motion in seated treatments. In this review, economical and clinical reasons for an upright patient positioning system are discussed. Existing designs targeted for particle therapy are reviewed, and conclusions are drawn on the design and construction of chair systems and associated image guidance. Finally, the different aspects from literature are channeled into recommendations for potential upright treatment layouts, both for retrofitting and new facilities.

Indexed as

image guidanceparticle therapyseated treatmenttreatment chairupright CTupright treatment

Identifiers

PMID35965576
PMCPMC9372451

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.