Evidence map›Paper›PMID 35962832›Full record

ArticleSurgical and radiologic anatomy : SRA2022

3D kinematic characteristics of lumbar facet joints in sitting position.

Ye Han, Kepeng Li, Xiaodong Wang, Jianzhong Wang, Shaosong Sun, Xi Xia, Jing Wang, Jun Miao

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical and radiologic anatomy : SRA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Ye Han *Department of Orthopedics, The Affiliated Hospital of Hebei University, Baoding, Hebei, China.ORCID http://orcid.org/0000-0002-2180-2817
Kepeng Li *Department of Orthopedics, The Second Central Hospital of Baoding, Baoding, Hebei, China.
Xiaodong WangDepartment of Orthopedics, The Affiliated Hospital of Hebei University, Baoding, Hebei, China.
Jianzhong WangDepartment of Orthopedics, The Affiliated Hospital of Hebei University, Baoding, Hebei, China.
Shaosong SunDepartment of Orthopedics, The Affiliated Hospital of Hebei University, Baoding, Hebei, China.
Xi XiaDepartment of Orthopedics, Baoding First Central Hospital, Baoding, Hebei, China.
Jing WangDepartment of Orthopedics, Gaoyang County Hospital, Baoding, Hebei, China.
Jun MiaoDepartment of Orthopedics, Tianjin Hospital of Tianjin University, Tianjin, China. mj6688@163.com.ORCID http://orcid.org/0000-0001-6689-4316
Affiliated Hospital of Hebei University · CNBaoding People's Hospital · CNTianjin University · CN

Funding

Foundation of S&T Program of Hebei Province 21377762Dthe Foundation of Baoding Self-raised Fund Project 2041ZF320
6 · The paper itself

Abstract

backgroundRecognizing the kinematic characteristics of lumbar facet joints is important for the prevention and treatment of lumbar degenerative diseases. Previous studies have been conducted in either the supine or standing position, and there are no measurements regarding the kinematic characteristics of the lumbar facet joints while sitting. The aim of this study was to measure and analyze lumbar facet joint motion characteristics while sitting.

methodsTen subjects (5 males and 5 females) performed the movements of flexion-extension, left bending-right bending, and left rotation-right rotation in a sitting position. Dual Fluoroscopic Image System and computed tomography technique were used to measure the displacement and rotation angle of the lumbar facet joints of the subjects for analysis. The movement characteristics of L3-S1 were measured.

resultsWhen the subjects were in sitting position, the lumbar vertebra mainly changed in Z-axis and α, β angle when they performed flexion-extension activities. The displacement of the left facet joint was 4.65 ± 1.99 mm at L3-4, 1.89 ± 2.99 mm at L4-5, and 0.80 ± 2.27 mm at L5-S1 in the Z-axis, and the displacement of the right facet joint was 3.20 ± 2.61 mm at L3-4, 1.71 ± 3.00 mm at L4-5, and 0.31 ± 1.69 mm at L5-S1 in the Z-axis. The rotation in the α angle was 6.00 ± 4.49° at L3-4, 3.51 ± 5.24° at L4-5, and 0.97 ± 4.13° at L5-S1, which was significant different. The rotation in the β angle was 2.30 ± 2.94°at L3-4, 0.16 ± 2.06° at L4-5, and 0.35 ± 1.74°at L5-S1, which was significant different. When the lumbar spine performed the activity of left bending-right bending, there were changes in rotation mainly in the Z-axis and β angle. The displacement of left facet joint in the Z-axis was 1.34 ± 2.84 mm at L3-4, 2.11 ± 0.88 mm at L4-5, and 0.72 ± 0.81 mm at L5-S1; the rotation in the β angle was 5.66 ± 2.70°at L3-4, 7.89 ± 2.59° at L4-5, and 1.28 ± 2.07° at L5-S1; when the lumbar spine performed the activity of left rotation-right rotation, there were changes in the β angle. The rotation of β angle was 4.09 ± 2.86° at L3-4, 2.14 ± 3.38° at L4-5, and 0.63 ± 1.85° at L5-S1.

conclusionThe lumbar facet joint motion in sitting position is different in each mode of motion. The horizontal displacement and rotation are predominant during flexion and extension activities, while there are different rotation in bending and rotation. The study shows the coupled motion of the lumbar facet joints while sitting, providing a new perspective on the kinematics of the lumbar spine and the etiology of lumbar degenerative diseases.

Indexed as

Zygapophyseal JointBiomechanical PhenomenaFemaleHumansLumbar VertebraeMaleRange of Motion, ArticularSitting PositionDFISKinematicLumbar facet jointsSitting

Identifiers

PMID35962832
OpenAlexW4291221426

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.