Evidence map›Paper›PMID 35962019›Full record

ArticleScientific reports2022

Coupled power generators require stability buffers in addition to inertia.

Gurupraanesh Raman, Gururaghav Raman, Jimmy Chih-Hsien Peng

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Gurupraanesh Raman *Department of Electrical and Computer Engineering, National University of Singapore, 2 Engineering Drive 3, Singapore, 117581, Singapore.
Gururaghav Raman *Department of Electrical and Computer Engineering, National University of Singapore, 2 Engineering Drive 3, Singapore, 117581, Singapore.
Jimmy Chih-Hsien PengDepartment of Electrical and Computer Engineering, National University of Singapore, 2 Engineering Drive 3, Singapore, 117581, Singapore. jpeng@nus.edu.sg.

Funding

National Research Foundation Singapore Future Resilient Systems ProgrammeSingapore Ministry of Education Academic Research Fund Tier-1 A-8000214-01-00
6 · The paper itself

Abstract

Increasing the inertia is widely considered to be the solution to resolving unstable interactions between coupled oscillators. In power grids, Virtual Synchronous Generators (VSGs) are proposed to compensate for reducing inertia as rotating fossil-fuel-based generators are being phased out. Yet, modeling how VSGs and rotating generators simultaneously contribute energy and inertia, we surprisingly find that instabilities of a small-signal nature could arise despite fairly high system inertia if the generators' controls are not coordinated at the system level. Importantly, we show there exist both an optimal and a maximum number of such VSGs that can be safely supported, a previously unknown result directly useful for power utilities in long-term planning and prosumer contracting. Meanwhile, to resolve instabilities in the short term until system-level coordination can be achieved, we argue that the new market should include another commodity that we call stability storage, whereby-analogous to energy storage buffering energy imbalances-VSGs act as decentralized stability buffers. While demonstrating the effectiveness of this concept for a wide range of energy futures, we provide policymakers and utilities with a roadmap towards achieving a 100% renewable grid.

Identifiers

PMID35962019
PMCPMC9374790

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.