ArticleFrontiers in neurology2022
The Anch'Or Harpoon Technique With a Manually Expandable Stentretriever (Tigertriever 13), a Technical Note.
Article in Frontiers in neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Prediction of catheter navigation difficulty during mechanical thrombectomy using CTA-based carotid siphon morphometry.Frontiers in medical technology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose: Stent and balloon anchor techniques have been described to obtain distal support and straighten catheter loops, stabilize microcatheters in giant aneurysms, or access distal tortuous anatomy during thrombectomy. These techniques require catheterization of distal arteries with a microcatheter but tortuosity and length issues may render it challenging, precluding the distal unsheathing of a classical auto-expandable stentretriever with the anchor technique. Methods: Therefore, we developed the so-called Anch'Or Harpoon Technique using a manually expandable stent retriever, the Tigertriever 13 (Rapid Medical, Yoqneam, Israel). Here, the stent retriever is not unsheathed but pushed out of a microcatheter, and then advanced as far as possible before manual opening. Results and conclusion: This technique may be used in 2 different situations. First, in the case of vessel tortuosity if the microcatheter can't be advanced as far as the physician wants: the Tigertriever 13 could be delivered through the microcatheter without having to unsheathe it, and be advanced and opened distally to its microcatheter to establish a stable anchor prior to advancing the guiding, intermediate, and micro-catheters (Anchor technique). The second situation is when distal occlusions lead to length issues; the microcatheter may be too short to cross a distal clot: the Tigertriever 13 could then be pushed out of the microcatheter, and be used to cross a sub-occlusive clot as it has a soft shaped distal tip and the physician has a visual on the artery beyond the sub-occlusion. Then, the Tigertriever would be manually expanded through the clot and retrieved (Harpoon technique) to obtain a recanalization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.