Evidence map›Paper›PMID 35958508›Full record

ArticleAmerican journal of translational research2022

Biomechanical effect of Coflex and X-STOP spacers on the lumbar spine: a finite element analysis.

Zhiyuan Guo, Guangfei Liu, Lu Wang, Yuejiang Zhao, Ye Zhao, Shouliang Lu, Cai Cheng

Open access · greenAbstract read
In one paragraph

Article in American journal of translational research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Evaluating 5-year outcomes of interlaminar devices as an adjunct to decompression for symptomatic lumbar spinal stenosis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Zhiyuan GuoDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Guangfei LiuDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Lu WangDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Yuejiang ZhaoDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Ye ZhaoDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Shouliang LuDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Cai ChengDepartment of Orthopedics, Cangzhou Central Hospital Cangzhou, Hebei, China.
Cangzhou Central Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo explore the biomechanical differences between Coflex and X-STOP devices by finite element analysis.

methodsBased on the normal lumbar CT images from a healthy adult volunteer, four finite element models including the healthy lumbar segment model, the mild degenerated lumbar segment model, a Coflex fixed lumbar segment model and X-STOP fixed lumbar segment model were constructed. A simulation analysis under the conditions of flexion, extension, lateral bending, and rotation was performed to compare range of motion (ROM), intradiscal pressure, the facet joint force, the maximum Von Mises stress and the peak facet contact forces, between Coflex and X-STOP devices.

resultsCompared to the mild degenerated lumbar segment model at surgical level L4-L5, Coflex and X-STOP could reduce ROM in extension by 98.34% and 95.86%, respectively, decrease peak stress of intervertebral discs in extension by 59.4% and 66.17%, respectively, and release peak force of facet joint in extension by 97.09% and 95.42%, respectively. Both devices had no significant impact on adjacent levels. The maximum Von Mises stress in Coflex device was 637.56 Mpa in flexion, 528.86 Mpa in extension, while the maximum Von Mises stress in X-STOP device was 476.65 Mpa at extension position. The peak facet contact forces of Coflex and X-STOP devices appeared in extension and were 19.76 Mpa and 49.28 Mpa, respectively.

conclusionsCoflex and X-STOP devices can effectively decrease the ROM and intradiscal pressure in extension, without affecting the adjacent levels.

Indexed as

biomechanical propertiesCoflexfinite element analysislumbar vertebraeX-STOP

Identifiers

PMID35958508
PMCPMC9360861
OpenAlexW4291708191

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.