Evidence map›Paper›PMID 35957701›Full record

ArticleClinical, cosmetic and investigational dentistry2022

Comparative Evaluation of Bulk-Fill Composite Resins: Knoop Microhardness, Diametral Tensile Strength and Degree of Conversion.

Bruna Scarcello Strini, Joyce Figueiredo de Lima Marques, Renata Pereira, Danielle Ferreira Sobral-Souza, Vanessa Gallego Arias Pecorari, Priscila Christiane Suzy Liporoni, Flávio Henrique Baggio Aguiar

Abstract read
In one paragraph

Article in Clinical, cosmetic and investigational dentistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bruna Scarcello StriniDepartment of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
Joyce Figueiredo de Lima MarquesDepartment of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID 0000-0001-7800-1255
Renata PereiraDepartment of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID 0000-0002-7865-3365
Danielle Ferreira Sobral-SouzaDental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil.ORCID 0000-0001-6147-964X
Vanessa Gallego Arias PecorariDepartment of Biostatistics, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID 0000-0002-0300-5697
Priscila Christiane Suzy LiporoniDepartment of Restorative Dentistry, University of Taubate, Taubaté, SP, Brazil.ORCID 0000-0001-6787-1167
Flávio Henrique Baggio AguiarDepartment of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID 0000-0003-3389-5536

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Bulk-fill composite resins were developed to reduce time and facilitate the restorative procedure. However, considering their recent introduction on the market and the new formulations, their performance still requires evaluation. This study aimed to evaluate Knoop microhardness (KHN), diametral tensile strength (DTS) and degree of conversion (DC) of three Bulk-Fill composite resins and a conventional one. Materials and Methods: Sixty samples (n = 15; 8 mm ø x 4 mm height) were confectioned using a mold. Filtek Bulk-Fill (FBF), Tetric N-Ceram Bulk-Fill (TNC) and SonicFill 2 (SF2) were placed in 4 mm increments, and Filtek Z350 (FZ350) was placed in 2 mm increments. The KHN of top and bottom surfaces were tested using Knoop Hardness tester at 10 gf/10s. The DTS was tested under compressive load at 1.0 mm/min. The DC was measured by Fourier Transform Infrared (FTIR) spectroscopy. Differences in DTS and DC were analyzed by ANOVA and Tukey post hoc test. For KHN, Kruskal-Wallis and Wilcoxon tests were performed at α = 0.05. Results: Top surfaces of all composite resins had higher KHN than bottom surfaces. At top and bottom surfaces, FZ350 showed higher KHN than TNC and SF2. The highest DTS was obtained by FBF, followed by FZ350 and SF2. The highest DC was obtained by SF2, the lowest one was obtained by FBF. Conclusion: From Bulk-Fill composite resins, FBF presented the best KHN and DTS results. The SF2 showed the best DC. Further studies are required to ensure whether these differences can negatively influence the behavior of in vivo restorations.

Indexed as

Bulk-Fillcomposite resinsFTIRhardnesstensile strength

Identifiers

PMID35957701
PMCPMC9359371

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.