Evidence map›Paper›PMID 35957376›Full record

ArticleSensors (Basel, Switzerland)2022

Assessment of a Therapeutic X-ray Radiation Dose Measurement System Based on a Flexible Copper Indium Gallium Selenide Solar Cell.

Dong-Seok Shin, Tae-Ho Kim, Jeong-Eun Rah, Dohyeon Kim, Hye Jeong Yang, Se Byeong Lee, Young Kyung Lim, Jonghwi Jeong, Haksoo Kim, Dongho Shin and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Dong-Seok ShinProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Tae-Ho KimProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Jeong-Eun RahDepartment of Radiation Oncology, Myongji Hospital, Goyang 10475, Korea.
Dohyeon KimProton Therapy Center, National Cancer Center, Goyang 10408, Korea.ORCID 0000-0003-2923-5148
Hye Jeong YangProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Se Byeong LeeProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Young Kyung LimProton Therapy Center, National Cancer Center, Goyang 10408, Korea.ORCID 0000-0002-4176-6518
Jonghwi JeongProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Haksoo KimProton Therapy Center, National Cancer Center, Goyang 10408, Korea.ORCID 0000-0001-8983-5423
Dongho ShinProton Therapy Center, National Cancer Center, Goyang 10408, Korea.
Jaeman SonDepartment of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Korea.

Funding

National Cancer Center 2010140-3National Cancer Center 2110370-2National Research Foundation of Korea 2021M2E8A1049195
6 · The paper itself

Abstract

Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.

Indexed as

CopperIndiumGalliumHumansRadiation DosageRadiometrySeleniumX-RaysCopperGalliumgallium selenideIndiumSeleniumcopper indium gallium selenide solar cellflexible dosimeterradiation therapy

Identifiers

PMID35957376
PMCPMC9370937

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.