Evidence map›Paper›PMID 35957369›Full record

ArticleSensors (Basel, Switzerland)2022

Comparative Study of Measurement Methods for Embedded Bioimpedance Spectroscopy Systems.

Bilel Ben Atitallah, Ahmed Yahia Kallel, Dhouha Bouchaala, Nabil Derbel, Olfa Kanoun

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. A New Technique to Estimate the Cole Model for Bio-impedance Spectroscopy with the High-Frequency Characteristics Estimation.... International Conference on Wearable and Implantable Body Sensor Networks. International Conference on Wearable and Implantable Body Sensor Networks · 2023
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Bilel Ben AtitallahFaculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany.ORCID 0000-0003-2808-5002
Ahmed Yahia KallelFaculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany.ORCID 0000-0003-3689-6518
Dhouha BouchaalaNational Engineering School of Sfax, University of Sfax, Sfax 3038, Tunisia.ORCID 0000-0003-4316-1616
Nabil DerbelNational Engineering School of Sfax, University of Sfax, Sfax 3038, Tunisia.ORCID 0000-0002-2875-562X
Olfa KanounFaculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany.ORCID 0000-0002-7166-1266
University of Sfax · TNChemnitz University of Technology · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bioimpedance spectroscopy (BIS) is an advanced measurement method for providing information on impedance changes at several frequencies by injecting a low current into a device under test and analyzing the response voltage. Several methods have been elaborated for BIS measurement, calculating impedance with a gain phase detector (GPD), IQ demodulation, and fast Fourier transform (FFT). Although the measurement method has a big influence on the measurement system performance, a systematical comparative study has not been performed yet. In this paper, we compare them based on simulations and experimental studies. To maintain similar conditions in the implementation of all methods, we use the same signal generator followed by a voltage-controlled current source (VCCS) as a signal generator. For performance analysis, three DUTs have been designed to imitate the typical behavior of biological tissues. A laboratory impedance analyzer is used as a reference. The comparison addresses magnitude measurement accuracy, phase measurement accuracy, signal processing, hardware complexity, and power consumption. The result shows that the FFT-based system excels with high accuracy for amplitude and phase measurement while providing the lowest hardware complexity, and power consumption, but it needs a much higher software complexity.

Indexed as

Signal Processing, Computer-AssistedSoftwareDielectric SpectroscopyElectric ImpedanceFourier AnalysisSpectrum Analysisbioimpedancebioimpedance spectroscopyembedded impedance spectroscopyFFTGPDIQ demodulation

Identifiers

PMID35957369
PMCPMC9371087
OpenAlexW4289731416

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.