ArticleSensors (Basel, Switzerland)2022
Effects of Missing Data on Heart Rate Variability Metrics.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Signal Quality Assessment and Reconstruction of PPG-Derived Signals for Heart Rate and Variability Estimation in In-Vehicle Applications: A Comparative Review and Empirical Validation.Sensors (Basel, Switzerland) · 2025Review
- Alterations in the autonomic and haemodynamic response to prolonged high-intensity endurance exercise in individuals with coronary artery calcification.Experimental physiology · 2025Article
- Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study.JMIR formative research · 2025Observational
- Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring.Sensors (Basel, Switzerland) · 2024Article
- Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life.Sensors (Basel, Switzerland) · 2024Article
- Aligned bodies, united hearts: embodied emotional dynamics of an Islamic ritual.Philosophical transactions of the Royal Society of London. Series B, Biological sciences · 2024Article
- Data-Fusion-Based Quality Enhancement for HR Measurements Collected by Wearable Sensors.Sensors (Basel, Switzerland) · 2024Article
- Cardiac sensing at a spinal cord stimulation lead: a promising on-device potential biomarker for pain and wellbeing.Frontiers in physiology · 2024Article
- Optimizing support vector machines and autoregressive integrated moving average methods for heart rate variability data correction.MethodsX · 2023Article
- Multifractal foundations of biomarker discovery for heart disease and stroke.Scientific reports · 2023Article
- Advances in Wearable Photoplethysmography Applications in Health Monitoring.Sensors (Basel, Switzerland) · 2023Article
- A Novel Adaptive Noise Elimination Algorithm in Long RR Interval Sequences for Heart Rate Variability Analysis.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.