ArticleSensors (Basel, Switzerland)2022
Fiber-Optic Temperature Sensor Using Cholesteric Liquid Crystals on the Optical Fiber Ferrules.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 9 citations in OpenAlex.
- Equivalent Refractive Index Modeling and Multidomain Characterization of the Temperature Response of Loss in Fiber-Optic Macro-Bends.Sensors (Basel, Switzerland) · 2026Article
- Output Characterization of 220 nm Broadband 1250 nm Wavelength-Swept Laser for Dynamic Optical Fiber Sensors.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
Cholesteric liquid crystals (CLCs) can be applied to various physical and chemical sensors because their alignment structures are changed by external stimuli. Here, we propose a CLC device fabricated by vertically forming the helical axis of the CLC between the cross-sections of two optical fiber ferrules. An optical fiber temperature sensor was successfully implemented using the proposed optical fiber ferrule-based CLC device. A wideband wavelength-swept laser with a center wavelength of 1073 nm and scanning range of 220 nm was used as a light source to measure the variations in the reflection spectrum band according to the temperature change in the CLC cell. The wavelength variation of the reflection spectrum band according to the temperature applied to the CLC cell was reversible and changed linearly with a change in the temperature, and the long-wavelength edge variation rate according to the temperature change was -5.0 nm/°C. Additionally, as the temperature applied to the CLC cell increased, the reflection spectrum bandwidth gradually decreased; the reflection spectrum bandwidth varied at a rate of -1.89 nm/°C. The variations in the refractive indices with temperature were calculated from the band wavelengths of the reflection spectrum. The pitch at each temperature was calculated based on the refractive indices and it gradually decreased as the temperature increased.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.