Evidence map›Paper›PMID 35957229›Full record

ArticleSensors (Basel, Switzerland)2022

PLC-Based Integrated Refractive Index Sensor Probe with Partially Exposed Waveguide.

Jin Hwa Ryu, Hoesung Yang, Soyoung Park, Soocheol Kim, Kyuwon Han, Hyunseok Kim, Kwangsoo Cho, Kang Bok Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jin Hwa RyuIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.ORCID 0000-0001-9312-8502
Hoesung YangIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Soyoung ParkIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Soocheol KimIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Kyuwon HanIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Hyunseok KimIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Kwangsoo ChoIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.
Kang Bok LeeIndustrial & Personal Safety Intelligence Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea.ORCID 0000-0001-9508-5577

Funding

Korea government (MIST) No. 2020-0-00012
6 · The paper itself

Abstract

This paper proposes a simple, high-efficiency refractive index (RI) sensor, with a structure based on the planar lightwave circuit (PLC) probe type. The optical sensor has a 1 × 2 splitter structure with reference and sensing channels, each consisting of a U-shaped waveguide structure that is configured by connecting C bends. This design allows for the sensor device to have a probe structure wherein the surface interconnected with activity devices (i.e., an optical source and optical detector) is placed on one side. The reference channel is bent with a minimum optical loss, and the sensing channel has a bent structure, involving a C-bend waveguide with a maximum loss. The C-bend waveguide with a maximum loss is conformally aligned to have a trench structure with the same bending radius, designed to selectively expose the sidewall of the core layer. The local index contrast varies depending on the material in contact with the trench, resulting in a change in the optical output power of the waveguide. The sensitivity of the proposed sensor was 0 and 2070 μW/refractive index unit (RIU) for the reference and sensing channels, respectively, as the RI changed from 1.385 to 1.445 at a 1550 nm wavelength. These results suggest that the proposed structure enables efficient RI measurement through the use of a simple dip-type method.

Indexed as

RefractometrySurface Plasmon Resonanceindex contrastintegrated PLC proberefractive index sensortrenchU-shaped waveguide

Identifiers

PMID35957229
PMCPMC9370853

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.