Evidence map›Paper›PMID 35957186›Full record

ArticleSensors (Basel, Switzerland)2022

Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks.

Pauline Morin, Antoine Muller, Charles Pontonnier, Georges Dumont

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pauline MorinUniversity Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, France.
Antoine MullerUniversity Lyon, University Gustave Eiffel, University Claude Bernard Lyon 1, LBMC UMR_T 9406, 69622 Lyon, France.ORCID 0000-0003-2606-1429
Charles PontonnierUniversity Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, France.ORCID 0000-0003-1140-3772
Georges DumontUniversity Rennes, CNRS, Inria, IRISA-UMR 6074, 35000 Rennes, France.ORCID 0000-0002-0709-0921

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon® pressure insoles during sidestep cuts, runs and walks. The CoP positions assessed from force platform data and from pressure insole data were compared. One calibration trial performed on the force platforms was used to localize the insoles in the reference coordinate system. The most accurate results were obtained when the motion performed during the calibration trial was similar to the motion under study. In such a case, mean accuracy of CoP position have been evaluated to 15±4mm along anteroposterior (AP) axis and 8.5±3mm along mediolateral (ML) axis for sidestep cuts, 18±5mm along AP axis and 7.3±4mm along ML axis for runs, 15±6mm along AP axis and 6.6±3mm along ML axis for walks. The accuracy of the CoP position assesment from pressure insole data increased with the vertical force applied to the pressure insole and with the number of pressure cells involved.

Indexed as

Foot OrthosesShoesBiomechanical PhenomenaFootMotionPressurebiomechanicsground reaction forcesmoticonmotion analysisoutside laboratory experiments

Identifiers

PMID35957186
PMCPMC9370979

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.