Evidence map›Paper›PMID 35957026›Full record

ArticleNanomaterials (Basel, Switzerland)2022

Hyperelastic Microcantilever AFM: Efficient Detection Mechanism Based on Principal Parametric Resonance.

Amin Alibakhshi, Sasan Rahmanian, Shahriar Dastjerdi, Mohammad Malikan, Behrouz Karami, Bekir Akgöz, Ömer Civalek

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 5 countries.

Amin AlibakhshiDepartment of Mechanical Engineering, Science and Research Branch, Islamic Azad University, Tehran 1477893855, Iran.ORCID 0000-0003-3010-3548
Sasan RahmanianDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Shahriar DastjerdiDivision of Mechanics, Civil Engineering Department, Akdeniz University, Antalya 07058, Turkey.ORCID 0000-0003-4256-240X
Mohammad MalikanDepartment of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gabriela Narutowicza 11/12, 80-233 Gdańsk, Poland.ORCID 0000-0001-7356-2168
Behrouz KaramiDepartment of Mechanical Engineering, Marvdasht Branch, Islamic Azad University, Marvdasht 73711-13119, Iran.ORCID 0000-0002-8191-0000
Bekir AkgözDivision of Mechanics, Civil Engineering Department, Akdeniz University, Antalya 07058, Turkey.ORCID 0000-0003-2097-2555
Ömer CivalekDivision of Mechanics, Civil Engineering Department, Akdeniz University, Antalya 07058, Turkey.ORCID 0000-0003-1907-9479
Akdeniz University · TRChina Medical University · TWGdańsk University of Technology · PLIslamic Azad University, Marvdasht · IRIslamic Azad University, Science and Research Branch · IRUniversity of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The impetus of writing this paper is to propose an efficient detection mechanism to scan the surface profile of a micro-sample using cantilever-based atomic force microscopy (AFM), operating in non-contact mode. In order to implement this scheme, the principal parametric resonance characteristics of the resonator are employed, benefiting from the bifurcation-based sensing mechanism. It is assumed that the microcantilever is made from a hyperelastic material, providing large deformation under small excitation amplitude. A nonlinear strain energy function is proposed to capture the elastic energy stored in the flexible component of the device. The tip-sample interaction is modeled based on the van der Waals non-contact force. The nonlinear equation governing the AFM's dynamics is established using the extended Hamilton's principle, obeying the Euler-Bernoulli beam theory. As a result, the vibration behavior of the system is introduced by a nonlinear equation having a time-dependent boundary condition. To capture the steady-state numerical response of the system, a developed Galerkin method is utilized to discretize the partial differential equation to a set of nonlinear ordinary differential equations (ODE) that are solved by the combination of shooting and arc-length continuation method. The output reveals that while the resonator is set to be operating near twice the fundamental natural frequency, the response amplitude undergoes a significant drop to the trivial stable branch as the sample's profile experiences depression in the order of the picometer. According to the performed sensitivity analysis, the proposed working principle based on principal parametric resonance is recommended to design AFMs with ultra-high detection resolution for surface profile scanning.

Indexed as

atomic force microscopydeveloped Galerkin methodhyperelastic microcantilevernon-contact cantilevershooting and arc-length continuation methodsoftening resonance

Identifiers

PMID35957026
PMCPMC9370785
OpenAlexW4288721968

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked