Evidence map›Paper›PMID 35955986›Full record

ArticleJournal of clinical medicine2022

Metal Artifact Reduction Sequences MRI: A Useful Reference for Preoperative Diagnosis and Debridement Planning of Periprosthetic Joint Infection.

Changyu Huang, Yang Chen, Haiqi Ding, Zida Huang, Chaofan Zhang, Wenbo Li, Xi Liu, Zhanhai Tu, Wenming Zhang, Xinyu Fang

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Advances in Bone Joint Imaging-Metal Artifact Reduction.Diagnostics (Basel, Switzerland) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Changyu HuangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Yang ChenDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.ORCID 0000-0001-7168-7098
Haiqi DingDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Zida HuangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.ORCID 0000-0002-5204-2005
Chaofan ZhangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Wenbo LiDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Xi LiuDepartment of Radiology and Imaging, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Zhanhai TuDepartment of Radiology and Imaging, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Wenming ZhangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Xinyu FangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Fujian Medical University · CN

Funding

National Natural Science Foundation of China 82072458, 82171370
6 · The paper itself

Abstract

The diagnosis and treatment of periprosthetic joint infection (PJI) is complex and the use of MRI in PJI is gaining attention from orthopedic surgeons as MR technology continues to advance. This study aimed to investigate whether metal artefact reduction sequence (MARS) MRI could be used as an adjunct in the preoperative diagnosis of PJI and to explore its role in PJI debridement planning. From January 2020 to November 2021, participants with metal joint prostheses that needed to be judged for infection were prospectively enrolled. According to Musculoskeletal Infection Society standards, 31 cases were classified as infection, and 20 as non-infection. The sensitivity and specificity of MARS MRI for the diagnosis of PJI were 80.65% and 75%, respectively. In MARS MRI, the incidence of bone destruction, lamellar synovitis, and extracapsular soft tissue oedema were significantly higher in PJI than in non-PJI. Fourteen suspicious occult lesions were found in the preoperative MARS MRI in 9 cases, and the location of 9 infection lesions was confirmed intraoperatively. In conclusion, MARS MRI is an effective diagnostic tool for PJIand can provide a visual reference for preoperative surgical planning.

Indexed as

diagnosismetal artifact reduction sequencesMRIperiprosthetic joint infection

Identifiers

PMID35955986
PMCPMC9369276
OpenAlexW4288077835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.