ArticleScientific reports2022
Wireless power transfer system for deep-implanted biomedical devices.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Clinical translation and engineering challenges of soft robotic cardiac sleeves for heart failure.Nature communications · 2026Review
- Evaluation of the Effectiveness of a Novel Wireless Energy-Transmitting Implantable Diaphragm Pacemaker in Anesthetized Pigs.Bioengineering (Basel, Switzerland) · 2026Article
- Open-source, low-cost 3D-printable testbed for in-body optical wireless communications research.HardwareX · 2026Article
- Design of a wideband RF rectifier for enhanced wireless power transfer in biomedical implants supporting white space WiFi and LTE bands.Scientific reports · 2025Article
- An implantable hydrogel-based phononic crystal for continuous and wireless monitoring of internal tissue strains.Nature biomedical engineering · 2025Article
- Measurement dataset of experimental in-body optical wireless communication test-bed for research purposes.Data in brief · 2025Article
- Development of an efficient mid-field wireless power transmission system for biotelemetric IoT medical devices.Scientific reports · 2025Article
- Ultrathin, Lightweight Materials Enabled Wireless Data and Power Transmission in Chip-Less Flexible Electronics.ACS materials Au · 2025Review
- Rotation insensitive implantable wireless power transfer system for medical devices using metamaterial-polarization converter.Scientific reports · 2024Article
- Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People.Sensors (Basel, Switzerland) · 2023Article
- Design of dual-band power amplifier using bandstop filter and dual-mode bias circuit for multistandard transceiver systems.Scientific reports · 2023Article
- A multiband SSr diode RF rectifier with an improved frequency ratio for biomedical wireless applications.Scientific reports · 2023Article
- Investigation of temperature variations on a Class-E inverter and proposing a compensation circuit to prevent harmful effects on biomedical implants.Scientific reports · 2023Article
- Comparative analysis of energy transfer mechanisms for neural implants.Frontiers in neuroscience · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper, a dual-band implantable rectenna is proposed for recharging and operating biomedical implantable devices at 0.915 and 2.45 GHz. The rectenna system consists of a compact dual-band antenna based on a meandered-resonator as well as efficient dual-band rectifier circuit. Both components (antenna and rectifier) are integrated inside a capsule device to simulate and experimentally validate the rectenna. The antenna occupies lower volume ([Formula: see text] [Formula: see text]), where compactness is achieved using meandered geometry and a slotted ground plane. It maintains quasi-omnidirectional radiation patterns and peak realized gains of -22.1 dBi (915 MHz) and -19.6 dBi (2.45 GHz); thus, its capability is enhanced to harvest the ambient energy from multiple directions. Moreover, a dual-band rectifier is designed using a dual-branch matching network (an L-matching network and open-circuited stub in each branch) with a radio frequency (RF) to direct current (DC) conversion efficiency of 79.9% for the input power of 1 dBm (lower band: 0.915 GHz) and 72.8% for the input power of 3 dBm (upper band: 2.45 GHz). To validate the concept of the rectenna, the implantable antenna and rectifier are fabricated and attached together inside a capsule device, with the measured results verifying the simulated responses. The proposed rectenna efficiently rectifies two RF signals and effectively superimposes on a single load, thus, providing a distinct advantage compared to single-band rectennas. To the best of the authors' knowledge, this is the first-ever implantable rectenna to perform dual-band RF signal rectification.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.