ArticleMedical physics2022

Validating the accuracy of multispectral metal artifact suppressed diffusion-weighted imaging.

John P Neri, Matthew F Koff, Kevin M Koch, Ek T Tan

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

John P NeriMRI Research Laboratory, Hospital for Special Surgery, New York, New York, USA.
Matthew F KoffMRI Research Laboratory, Hospital for Special Surgery, New York, New York, USA.
Kevin M KochCenter for Imaging Research, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
Ek T TanMRI Research Laboratory, Hospital for Special Surgery, New York, New York, USA.ORCID https://orcid.org/0000-0003-2847-9378
Hospital for Special Surgery · USMedical College of Wisconsin · US

Funding

The Ability of MRI to Detect Adverse Local Tissue Reaction and Implant Integration as a Function of Hip Implant ModularityR01AR064840 · NIAMS · HOSPITAL FOR SPECIAL SURGERY · PI KOFF, MATTHEW F., POTTER, HOLLIS G. · 2013 to 2023
$5.0M
A Complete Metal Artifact Reduced MRI Exam for NeuroimagingR21EB030123 · NIBIB · MEDICAL COLLEGE OF WISCONSIN · PI KOCH, KEVIN M, NENCKA, ANDREW S · 2021 to 2022
$429k
Enabling Diffusion-Weighted MRI Near Metallic ImplantsR21EB023415 · NIBIB · MEDICAL COLLEGE OF WISCONSIN · PI KOCH, KEVIN M · 2017 to 2018
$422k
NIAMS NIH HHS R01 AR064840NIBIB NIH HHS R21 EB023415NIBIB NIH HHS R21 EB030123
6 · The paper itself

Abstract

backgroundDiffusion-weighted imaging (DWI) provides quantitative measurement of random water displacement in tissue as calculated by the apparent diffusion coefficient (ADC). While heavily utilized in stroke and oncology applications, DWI is a promising tool to map microstructural changes in musculoskeletal applications including evaluation of synovial reactions resulting from total hip arthroplasty (THA). One major challenge facing the application of DWI in THA is the significant artifacts related to the conventional echo-planar imaging (EPI) readout used. Multispectral imaging (MSI) techniques, including the multiacquisition with variable resonance image combination (MAVRIC), have been shown to effectively reduce metallic susceptibility artifacts around total joint replacements to render clinically useful images. Recently, a 2D periodically rotated overlapping parallel line with enhanced reconstruction (PROPELLER) FSE acquisition that incorporates a diffusion preparation pulse with 2D-MAVRIC has been developed to mitigate both distortion and dropout artifacts. While there have been some preliminary assessments of DWI-MAVRIC, the repeatability of DWI-MAVRIC and the effects of key parameters, such as the number of spectral bins, are unknown. PURPOSE: To evaluate the quantitative accuracy of DWI-MAVRIC as compared to conventional diffusion sequences.

methodsA diffusion phantom with different reference diffusivities (ADC = 113-1123 μm

resultsDWI-MAVRIC had excellent correlation to reference values but at reduced linearity (r = 1.00, slope = 0.91-0.94) as compared to DWI-EPI (r = 1.00, slope = 0.99-1.01). A greater than 5% ADC bias was observed at the lowest ADC values, predominantly in the DWI-MAVRIC scans. ADC values did not vary with DWI-MAVRIC parameters. DWI-EPI acquisitions had intraday, interday, and interscanner repeatability of 3.18 μm

conclusionsDWI-MAVRIC provides good linearity with respect to reference values and good intra- and interday repeatability.

Indexed as

ArtifactsDiffusion Magnetic Resonance ImagingEcho-Planar ImagingReproducibility of ResultsWaterWaterdiffusionMRImultispectral imagingphantom

Identifiers

PMID35953390
PMCPMC9588535
OpenAlexW4291014580

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.