ArticleProceedings of SPIE--the International Society for Optical Engineering
Optical Coherence Tomography Feedback System for Infrared Laser Sealing of Blood Vessels.
Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Basic performance of domestic surgical robot and the safety and effectiveness of integrated energy equipment.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Infrared (IR) lasers have recently been tested as an alternative to electrosurgical and ultrasonic laparoscopic devices for optical sealing of blood vessels. IR laser technology previously demonstrated faster sealing times, reduced thermal spread, and lower device temperatures during experimental studies. However, current commercial laparoscopic devices incorporate electrical impedance and/or temperature sensors as real-time, closed-loop, feedback to indicate successful blood vessel seals. This preliminary study explores an infrared laser system for sealing and optical coherence tomography (OCT) as a potential feedback system for successful vessel seal verification. A 1470-nm diode laser delivered an incident power of 30 W for an irradiation time of 5 s using an 8 × 2 mm linear beam, for creating strong seals in porcine renal blood vessels under compression. After sealing the blood vessels, OCT was performed on unsealed and sealed vessel regions for comparison. Standard vessel burst pressure (BP) measurements confirmed successful seals after OCT. Integrated reflectance intensity in OCT A-scans decreased by an average of 20 ± 6% in sealed versus native vessels of 2.4 ± 0.4 mm diameter. Vessel BP measured 532 ± 239 mmHg, with all vessels (n = 25) recording a successful BP > 180 mmHg (hypertensive blood pressure). Unsealed vessels demonstrated significantly deeper imaging marked by a continuous decay in reflected intensity, while sealed vessels showed subsurface reflectance intensity peaks, immediately followed by a rapid decay in reflectance intensity. These markers are consistent with increased light scattering and decreased optical penetration depth upon thermal coagulation of tissues. A-line OCT data consistently differentiated between sealed and unsealed blood vessel regions. Future work will involve OCT integration into the laparoscopic device for real-time optical feedback during IR laser sealing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.