Evidence map›Paper›PMID 35950053›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering

Optical Coherence Tomography Feedback System for Infrared Laser Sealing of Blood Vessels.

Nicholas C Giglio, Haleigh M Grose, Nathaniel M Fried

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Basic performance of domestic surgical robot and the safety and effectiveness of integrated energy equipment.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Nicholas C GiglioDepartment of Physics and Optical Science, University of North Carolina at Charlotte, NC.
Haleigh M GroseDepartment of Mechanical Engineering, University of North Carolina at Charlotte, NC.
Nathaniel M FriedDepartment of Physics and Optical Science, University of North Carolina at Charlotte, NC.
University of North Carolina at Charlotte · US

Funding

Laser Sealing and Cutting of Vascular TissuesR15EB028576 · NIBIB · UNIVERSITY OF NORTH CAROLINA CHARLOTTE · PI FRIED, NATHANIEL M · 2019 to 2019
$453k
NIBIB NIH HHS R15 EB028576
6 · The paper itself

Abstract

Infrared (IR) lasers have recently been tested as an alternative to electrosurgical and ultrasonic laparoscopic devices for optical sealing of blood vessels. IR laser technology previously demonstrated faster sealing times, reduced thermal spread, and lower device temperatures during experimental studies. However, current commercial laparoscopic devices incorporate electrical impedance and/or temperature sensors as real-time, closed-loop, feedback to indicate successful blood vessel seals. This preliminary study explores an infrared laser system for sealing and optical coherence tomography (OCT) as a potential feedback system for successful vessel seal verification. A 1470-nm diode laser delivered an incident power of 30 W for an irradiation time of 5 s using an 8 × 2 mm linear beam, for creating strong seals in porcine renal blood vessels under compression. After sealing the blood vessels, OCT was performed on unsealed and sealed vessel regions for comparison. Standard vessel burst pressure (BP) measurements confirmed successful seals after OCT. Integrated reflectance intensity in OCT A-scans decreased by an average of 20 ± 6% in sealed versus native vessels of 2.4 ± 0.4 mm diameter. Vessel BP measured 532 ± 239 mmHg, with all vessels (n = 25) recording a successful BP > 180 mmHg (hypertensive blood pressure). Unsealed vessels demonstrated significantly deeper imaging marked by a continuous decay in reflected intensity, while sealed vessels showed subsurface reflectance intensity peaks, immediately followed by a rapid decay in reflectance intensity. These markers are consistent with increased light scattering and decreased optical penetration depth upon thermal coagulation of tissues. A-line OCT data consistently differentiated between sealed and unsealed blood vessel regions. Future work will involve OCT integration into the laparoscopic device for real-time optical feedback during IR laser sealing.

Indexed as

blood vesselburst pressurescoagulationcompressionlaseroptical coherence tomography

Identifiers

PMID35950053
PMCPMC9361300
OpenAlexW4213203907

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.