ArticleJournal of applied clinical medical physics2022

Design of a novel 5-camera surface guidance system with multiple imaging isocenters.

Ozgur Ates, Li Zhao, David Sobczak, Fakhriddin Pirlepesov, Chia-Ho Hua, Ben Waghorn, Thomas E Merchant

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Ozgur AtesDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
Li ZhaoDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
David SobczakDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
Fakhriddin PirlepesovDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
Chia-Ho HuaDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
Ben WaghornVision RT Inc., London, UK.
Thomas E MerchantDepartment of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
St. Jude Children's Research Hospital · USVision RT (United Kingdom) · GB

Funding

Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
6 · The paper itself

Abstract

PURPOSE/OBJECTIVE(S): Surface-guided radiation therapy (SGRT) can track the patient surface noninvasively to complement radiographic image-guided radiation therapy with a standard 3-camera system and a single radiation/image isocenter. Here we report the commissioning of a novel SGRT system that monitors three imaging isocenters locations in a proton half-gantry room with a unique 5-camera configuration. MATERIALS/

methodsThe proton half-gantry room has three image isocenters, designated ISO-0, ISO-1, and ISO-2, to cover various anatomical sites via a robotic ceiling-mounted cone-beam CT. Although ISO-0 and ISO-1 are used to image the cranium, head and neck, and thoracic regions, ISO-2 is often used to image body and extremity sites and contiguous craniospinal target volumes. The five-camera system was calibrated to the radiographic isocenter by using a stereotactic radiosurgery cube phantom for each image isocenter.

resultsThe performance of this 5-camera system was evaluated for 6 degrees of freedom in three categories: (1) absolute setup accuracy relative to the radiographic kV image isocenter based on the DICOM reference; (2) relative shift accuracy based on a reference surface capture; and (3) isocenter tracking accuracy from one isocenter to another based on a reference surface capture. The evaluation revealed maximum deviations of 0.8, 0.2, and 0.6 mm in translation and 0.2°, 0.1°, and 0.1° in rotation for the first, second, and third categories, respectively. Comparing the dosimetry and latency with static and gated irradiation revealed a 0.1% dose difference and positional differences of 0.8 mm in X and 0.9 mm in Y with less than 50 ms temporal accuracy.

conclusionThe unique 5-camera system configuration provides SGRT at the treatment isocenter (ISO-0) and also imaging isocenter locations (ISO-0, ISO-1, and ISO-2) to ensure correct patient positioning before and after radiographic imaging, especially during transitions from the offset imaging isocenters to the treatment isocenter.

Indexed as

ProtonsRadiotherapy, Image-GuidedCone-Beam Computed TomographyHumansPatient PositioningPhantoms, ImagingProtonsmultiple imaging isocentersproton therapySGRTsurface-guided radiation therapy

Identifiers

PMID35946854
PMCPMC9588261
OpenAlexW4297831047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.