What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveFinger splints are used as a treatment option in tendon, bone, and soft tissue injuries. For immobilization, custom-made splints and prefabricated finger splints are used. In splints made for immobilization, it is aimed to limit joint movement. The aim of our study is to reveal how much custom-made splints and prefabricated finger splints limit joint motion (flexion angle in proximal interphalangeal and distal interphalangeal joints).
methodsCustom-made splints and prefabricated finger splints were applied to the second fingers of the dominant side in a total of 40 individuals, 20 women and 20 men, not having any health problems. Individuals were asked to flex and joint motion was measured with the iPhone compass application.
resultsThe mean distal interphalangeal joint angle values of the participants measured by prefabricated finger splints were found to be 24.27±8.29, and the mean distal interphalangeal joint angle values measured by custom-made splints was 0.52±1.50. There was a difference between the participants' distal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splint. The mean of the participants' proximal interphalangeal joint angle values measured by prefabricated finger splints was 16.55±7.90, and the proximal interphalangeal joint angle values measured by custom-made splints was "0" for all participants. There was a difference between the participants' proximal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). Distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splints.
conclusionAccording to our study, custom-made splints can significantly reduce the flexion of the finger interphalangeal joints compared to prefabricated finger splints.