Evidence map›Paper›PMID 35945668›Full record

ArticleJournal of biomedical optics2022

Precision of attenuation coefficient measurements by optical coherence tomography.

Linda B Neubrand, Ton G van Leeuwen, Dirk J Faber

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Linda B NeubrandAmsterdam UMC, Location AMC, University of Amsterdam, Department of Biomedical Engineering and Physics, Amsterdam, The Netherlands, The Netherlands.
Ton G van LeeuwenAmsterdam UMC, Location AMC, University of Amsterdam, Department of Biomedical Engineering and Physics, Amsterdam, The Netherlands, The Netherlands.
Dirk J FaberAmsterdam UMC, Location AMC, University of Amsterdam, Department of Biomedical Engineering and Physics, Amsterdam, The Netherlands, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceOptical coherence tomography (OCT) is an interferometric imaging modality, which provides tomographic information on the microscopic scale. Furthermore, OCT signal analysis facilitates quantification of tissue optical properties (e.g., the attenuation coefficient), which provides information regarding the structure and organization of tissue. However, a rigorous and standardized measure of the precision of the OCT-derived optical properties, to date, is missing.

aimWe present a robust theoretical framework, which provides the Cramér -Rao lower bound σμOCT for the precision of OCT-derived optical attenuation coefficients. APPROACH: Using a maximum likelihood approach and Fisher information, we derive an analytical solution for σμOCT when the position and depth of focus are known. We validate this solution, using simulated OCT signals, for which attenuation coefficients are extracted using a least-squares fitting procedure.

resultsOur analytical solution is in perfect agreement with simulated data without shot noise. When shot noise is present, we show that the analytical solution still holds for signal-to-noise ratios (SNRs) in the fitting window being above 20 dB. For other cases (SNR<20 dB, focus position not precisely known), we show that the numerical calculation of the precision agrees with the σμOCT derived from simulated signals.

conclusionsOur analytical solution provides a fast, rigorous, and easy-to-use measure for OCT-derived attenuation coefficients for signals above 20 dB. The effect of uncertainties in the focal point position on the precision in the attenuation coefficient, the second assumption underlying our analytical solution, is also investigated by numerical calculation of the lower bounds. This method can be straightforwardly extended to uncertainty in other system parameters.

Indexed as

Tomography, Optical CoherenceLeast-Squares AnalysisLikelihood FunctionsSignal-To-Noise Ratioattenuation coefficientCramér–Rao lower boundcurve-fittingFisher-information matrixmaximum likelihood estimationOCT signal simulationoptical coherence tomography

Identifiers

PMID35945668
PMCPMC9360497

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked