In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Observational
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Bo-Hyun SangDepartment of Anesthesiology and Pain Medicine, CHA Bundang Medical Cener, CHA University School of Medicine, Seongnam, Republic of Korea.ORCID 0000-0001-6890-4629
Changjin LeeDepartment of Anesthesiology and Pain Medicine, CHA Bundang Medical Cener, CHA University School of Medicine, Seongnam, Republic of Korea.
Da Yeong LeeDepartment of Anesthesiology and Pain Medicine, CHA Bundang Medical Cener, CHA University School of Medicine, Seongnam, Republic of Korea.
CHA University Bundang Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Maintaining body temperature in pediatric patients is critical, but it is often difficult to use currently accepted core temperature measurement methods. Several studies have validated the use of the SpotOn sensor for measuring core temperature in adults, but studies on pediatric patients are still lacking. The aim of this study was to investigate the accuracy of the SpotOn sensor compared with that of esophageal temperature measurement in pediatric patients intraoperatively. Children aged 1-8 years with American Society of Anesthesiology Physical Condition Classification I or II scheduled to undergo elective ear surgery for at least 30 min under general anesthesia were enrolled. Body core temperature was measured every 15 min after induction till the end of anesthesia with an esophageal probe, axillary probe, and SpotOn sensor. We included 49 patients, providing a total 466 paired measurements. Analysis of Pearson rank correlation between SpotOn and esophageal pairs showed a correlation coefficient (r) of 0.93 (95% confidence interval [CI] 0.92-0.94). Analysis of Pearson rank correlation between esophageal and axillary pairs gave a correlation coefficient (r) of 0.89 (95% CI 0.87-0.91). Between the SpotOn and esophageal groups, Bland-Altman analysis revealed a bias (SD, 95% limits of agreement) of -0.07 (0.17 [-0.41-0.28]). Between the esophageal and axillary groups, Bland-Altman analysis showed a bias (SD, 95% limits of agreement) of 0.45 (0.22 [0-0.89]). In pediatric patients during surgery, the SpotOn sensor showed high correlation and agreement with the esophageal probe, which is a representative core temperature measurement method.

Indexed as

Body TemperatureHot TemperatureAdultChildHumansMonitoring, IntraoperativeProspective StudiesTechnologyTemperature

Identifiers

PMID35939499
PMCPMC9359523
OpenAlexW4291020156

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.