ArticlePloS one2022
Prospective comparative analysis of noninvasive body temperature monitoring using zero heat flux technology (SpotOn sensor) compared with esophageal temperature monitoring during pediatric surgery.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 6 citations in OpenAlex.
- Core temperature measurement methods and their accuracy in pediatric intensive care units: a narrative review.Frontiers in pediatrics · 2026Review
- Numerical Investigation of Microporous Insulation for Power Reduction in Zero-Heat-Flux Thermometry.Micromachines · 2025Article
- Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study.Journal of anesthesia · 2024Observational
- Intraoperative hypothermia in patients with laparoscopic surgery: Influencing factors and prevention strategies.Heliyon · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Maintaining body temperature in pediatric patients is critical, but it is often difficult to use currently accepted core temperature measurement methods. Several studies have validated the use of the SpotOn sensor for measuring core temperature in adults, but studies on pediatric patients are still lacking. The aim of this study was to investigate the accuracy of the SpotOn sensor compared with that of esophageal temperature measurement in pediatric patients intraoperatively. Children aged 1-8 years with American Society of Anesthesiology Physical Condition Classification I or II scheduled to undergo elective ear surgery for at least 30 min under general anesthesia were enrolled. Body core temperature was measured every 15 min after induction till the end of anesthesia with an esophageal probe, axillary probe, and SpotOn sensor. We included 49 patients, providing a total 466 paired measurements. Analysis of Pearson rank correlation between SpotOn and esophageal pairs showed a correlation coefficient (r) of 0.93 (95% confidence interval [CI] 0.92-0.94). Analysis of Pearson rank correlation between esophageal and axillary pairs gave a correlation coefficient (r) of 0.89 (95% CI 0.87-0.91). Between the SpotOn and esophageal groups, Bland-Altman analysis revealed a bias (SD, 95% limits of agreement) of -0.07 (0.17 [-0.41-0.28]). Between the esophageal and axillary groups, Bland-Altman analysis showed a bias (SD, 95% limits of agreement) of 0.45 (0.22 [0-0.89]). In pediatric patients during surgery, the SpotOn sensor showed high correlation and agreement with the esophageal probe, which is a representative core temperature measurement method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.