Evidence map›Paper›PMID 35937097›Full record

ArticleApplied bionics and biomechanics2022

Force Transmission Analysis and Optimization of Bowden Cable on Body in a Flexible Exoskeleton.

Xin Li, Jinkang Liu, Weihao Li, Yijing Huang, Gan Zhan

Open access · goldAbstract read
In one paragraph

Article in Applied bionics and biomechanics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. A robotic emulator for the systematic exploration of transtibial biarticular prosthesis designs.Journal of rehabilitation and assistive technologies engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Xin LiSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.ORCID https://orcid.org/0000-0002-5147-2097
Jinkang LiuSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.
Weihao LiSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.
Yijing HuangSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.
Gan ZhanSchool of Mechatronics Engineering, Beijing Institute of Technology, Beijing 100081, China.
North China University of Technology · CNBeijing Institute of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Bowden cable is a significant force transmission equipment for a flexible exoskeleton. However, the previous researches of Bowden cable had emphasized on the data from experimenting test board, instead of on human body, which produced the inaccurate assisting analysis of the flexible exoskeleton. In this paper, a flexible exoskeleton for assisting knee extension was proposed, which provided an on-body condition. Then, the friction force and its influencing factors between the wire rope and sheath of the Bowden cable from the motor to the anchor of knee have been analyzed. The segment models of force transmission with the concern of three kinds of friction modes were established, and the relationship between various lengths and bending angles of Bowden cable was fitted to the equations of curve. Furthermore, the association rule between the force transmission and the lengths of Bowden cable was obtained, based on which, the optimal force transmission efficiency was 78.68% when the length value of the Bowden cable was 475 mm. A flexible exoskeleton prototype was assembled; then, the experiments with force transmission and metabolic cost have been developed. The results showed that the force transmission efficiency had strong association with the lengths of Bowden cable, instead of the transmission velocities. Furthermore, this knee assistance exoskeleton reduced the net metabolic cost of the testees during walking. These experiments results corroborated the force transmission modeling and simulation of the Bowden cable on body we proposed in this paper.

Identifiers

PMID35937097
PMCPMC9352506
OpenAlexW4288436219

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.